![Krone Bellima F 130 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/krone/bellima-f-130/bellima-f-130_original-operating-instructions_2004784082.webp)
10
Settings
10.7
Adjusting the sensors of the electronic baling pressure indicator
82
Bellima F 130
Original Operating Instructions 150000148_06_en
10.7
Adjusting the sensors of the electronic baling pressure indicator
RP000-224
The sensors (3) of the electronic baling pressure indicator are located on the right-hand and left-
hand machine sides behind the side hoods.
Make the following settings equally on the right-hand and left-hand side of the machine:
ü
The machine is shut down and safeguarded,
.
ü
The side hood is open.
Setting the sensor distance.
To check the dimension X between sensor (3) and control plate (4), set the black
preselection indicator (1) to the height of the red baling pressure indicator (2).
ð
The upper edge of the control plate (4) is located in the middle of the sensor (3).
Check dimension X.
ð
If the dimension is
X=3 mm
, the setting is correct.
ð
If the dimension is not
X=3 mm
, the sensor (3) must be set.
Loosen or tighten the screw connections of the sensor (3) until the dimension
X=3 mm
is
set.
Setting the control plate
If the indicator lamps of the electronic baling pressure indicator light up too soon or too late, the
control plate (4) must be set.
Loosen the screw connections (5) and change the position of the control plate (4) in the
oblong holes.
Switch the vehicle electrical system on.
Manually, move the red baling pressure indicator (2) to the black preselection indicator (1);
check whether the indicator lamps light up at the point in time when the two hands overlap.