![Krone Bellima F 130 Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/krone/bellima-f-130/bellima-f-130_original-operating-instructions_2004784094.webp)
11
Maintenance
11.3
Lubricating the universal shaft
94
Bellima F 130
Original Operating Instructions 150000148_06_en
11.3
Lubricating the universal shaft
RP000-176
ü
The machine is shut down and safeguarded,
.
Observe operating instructions of the universal shaft manufacturer.
Lubricate the universal shaft at the lubrication intervals indicated in the following table using
a multi-purpose grease.
For a list of the lubricating greases to be used,
The following table provides information on the lubricant quantity and the lubrication interval per
lubrication point.
Pos.
Lubricant quantity
Lubrication interval
(1)
10 g
50 hours
(2)
30 g
(3)
20 g
(4)
6 g
11.4
Tightening torques
Metric thread screws with control thread
INFORMATION
The table does not apply to countersunk screws with hexagon socket in case the countersunk
screw is tightened via hexagon socket.
DV000-001
X
Thread size
1
Strength class on screw head