sure the venting is installed properly to prevent leakage of carbon
monoxide into the mobile home.
4. If parts become damaged or need to be replaced, please contact your
local dealer or visit WWW.KOZISTOVES.COM. Do NOT replace
parts with any other parts not specified by your local dealer or
manufacturer.
II. Understanding Your Pellet Burning Heater
1. Component Description
1.1 General Overview
The first step in understanding your new
KOZI
heater is to familiarize yourself with its
operation. Your heater has 3 main systems: Combustion, Circulation and Feed. The
combustion system includes the air intake, burn pot, exhaust fan and exhaust venting.
The circulation system consists of a circulation fan, fan speed control and heat ex-
changer. The feed system is made up of an auger motor and various safety devices.
Each part of these systems will be described later in detail. A description of the
operation and the controls for your heater is provided in the section entitled “Heater
Operation”.
1.2 Exhaust Fan
The purpose of the exhaust fan is to remove the smoke from the combustion chamber.
The exhaust fan sucks air from the air intake, through the burn pot, around the heat
exchanger and pushes it through the venting. This fan is a fixed speed fan which turns
ON whenever the heater starts and remains ON until the heater is cool. THIS FAN
CANNOT BE TURNED OFF MANUALLY. Failure of this fan will result in a feed
system shut down.
1.3 Burn Pot
The burn pot is the receptacle in which the pellet fuel is burned. This portion of the
heater requires frequent cleaning since it controls the efficiency of the combustion
process. It is recommended the burn pot be cleaned every time the hopper is filled and
thoroughly scraped periodically.
DO NOT over fill the burn pot with too much fuel.
This can cause the heater to overfire and create damage to your heater.
1.4 Circulation Fan
The purpose of the circulation fan is to circulate the unheated room air through the heat
exchanger and back into the room as hot air. The circulation fan speed can be controlled
by the fan speed control (described later). The control system has a built-in safety that
allows it to override the fan speed control in the event the heater overheats. As your
heater begins to overheat, the circulation fan will come on high to remove some of the
excess heat. As your heater cools, the circulation fan will return to it’s original setting.
If the circulation fan cannot remove the heat fast enough, a second safety, the high
temperature manual reset disk, will shut the feed system OFF.