10. This heater is POWER VENTED. The vent pipes have positive
pressure during operation. It is IMPERATIVE that all joints in the
venting system be sealed to prevent any leakage of exhaust gases
inside the house. All joints must be sealed using high temperature
silicone sealer (RTV). Aluminum tape is not an adequate sealant.
11. Store all pellet fuel at a safe distance (at least 36 inches / 1 meter) away
from the heater and in a sealed metal container.
12. Use of outside combustion air is highly recommended and is manda-
tory in mobile home installations. Connect the air intake of the heater
to the exterior of the building with a non-combustible metal pipe with a
minimum diameter of 2 inches (50 mm) (Use APR Part No AK100).
Use of plastic pipes is not permitted. Where outside air cannot be used
in conventional homes, APR Part No CV100 (Check Valve) must be
used.
13. This appliance is wired and grounded according to the CSA C22.1
code for Canada and the NFPA 70 code for the USA. Also, this heater
meets the fuel burning appliance installation codes NFPA 211 in the
USA and CSA B365 in Canada.
14. Do NOT operate the heater with the door open. Make sure the door is
closed tightly during operation. Inspect the gaskets of the door
periodically to make sure they are in good condition.
15. Replace broken or defective components only with parts provided by
the manufacturer. See WWW.KOZISTOVES.COM or contact your
local dealer to find out how to purchase replacement parts.
16. Follow this manual carefully for proper installation. If you are
uncertain, call your dealer. Most dealers have qualified and trained
installers. We highly recommend the use of their services.
2. Clearance to Combustible Walls
Figure 1.
KOZI
pellet stove with a non-
combustible floor protector.
The following is a list of all minimum clearances to
combustibles for both the free standing stove as well as the
insert version.
2.1 Non-Combustible Floor Protector
A. Depth of Floor Protector
32 inches (815 mm)
B. Width of Floor Protector
27 inches (680 mm)
C. Floor Protector to Front of Unit
6 inches (150 mm)
D. Width of Unit
25 inches (635 mm)
E. Depth of Unit
25 inches (635 mm)