2.1 Circulation Fan Speed Control
The fan speed control is located on the top center of the control panel (see diagram).
Turning this knob counter-clockwise turns the circulation fan OFF. Rotating the knob
clockwise decreases the speed of the circulation fan from High to Low. It is NOT
recommended to leave this knob in the OFF position. When left in the OFF position, the
heater becomes over heated and the control circuit automatically overrides this switch
and puts the circulation fan on high speed.
2.4 Damper Control
The damper control rod is located on the left side of the heater. This rod controls the
amount of air passing through the burn pot. By pushing the control rod in, you reduce
the amount of air passing through the burn pot. By pulling the rod out, you will increase
the amount of air passing through the burn pot.
2.5 Starting (lighting) your Heater for the First Time
Once your heater is properly installed, complete the following steps to light it for the first
time or whenever your heater runs out of fuel:
1. Fill the hopper with pellet fuel. At this time the auger tube is empty. It
needs to be filled before the heater can be operated properly.
2. Turn the feed control knob clockwise to high.
3. Press the start button. The exhaust and circulation fan should come ON
and all 3 status lights should begin to blink.
4. Monitor the burn pot (located inside the burn chamber, see “Stove
Cross Section” diagram for exact location). Once pellet fuel begins to
drop into the burn pot, turn the feed control knob to medium (approxi-
mately 12 o’clock setting.). If the heater turns OFF before fuel begins
to drop into the burn pot, repeat steps 3 and 4.
Figure 17. Control panel
with controls
2.2 Start Button
The start button is located in the middle of the
control panel (see diagram). Pushing the start
button is the first step in starting the heater. The
heater will now run in manual operation mode
for 15 minutes. The heater will switch to the
automatic mode only if the heater reaches a
preset temperature. If this temperature is not
reached within 15 minutes the heater will shut
OFF. To allow the heater to run for another 15
minutes, simply press the start button once again
after the heater has shut OFF.
2.3 Feed Control
The feed control is a round knob located at the bottom of the control panel (see diagram).
Turning the knob in the counter-clockwise direction will turn the feed OFF. As the knob
is turned clockwise, the feed rate into the burn pot is increased, resulting in a bigger fire.