161
4.4 Error Code
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
4.4.6
Mechanical Control Error Code (04900 ~ 04908)
Type Error name Error description 04900~ 04908 indicates an error which can not be classi
fi
ed.
Error
code
Error name
Error description
Action
04900
Cassette exists when
initializing (Cassette
receive Unit)
The Cassette receive sensor was
On at the start of initialization
operations.
Open the front door, remove any cas-
settes, and then close the door and
restore. If restoration was not possible
(i.e., Ready is not achieved after com-
pletion of initialization operations), press
the Operation switch and perform a
restart after the power has turned off.
04901
Cassette exists when
initializing (justi
fi
ca-
tion)
The justi
fi
cation sensor-L or -R
was On at the start of initialization
operations.
Open the front door, remove any cas-
settes, and then close the door and
restore. If restoration was not possible
(i.e., Ready is not achieved after com-
pletion of initialization operations), press
the Operation switch and perform a
restart after the power has turned off.
04902
Cassette exists when
initializing (ejection
shutter open)
The eject shutter close sensor
was Off at the start of initialization
operations.
Open the front door, remove any cas-
settes, and then close the door and
restore. If restoration was not possible
(i.e., Ready is not achieved after com-
pletion of initialization operations), press
the Operation switch and perform a
restart after the power has turned off.
04903
Cassette exists when
initializing (absorbed
on back plate)
The back plate's Absorption
Detect sensor was On at the start
of initialization operations.
Open the front door, remove any cas-
settes, and then close the door and
restore. If restoration was not possible
(i.e., Ready is not achieved after com-
pletion of initialization operations), press
the Operation switch and perform a
restart after the power has turned off.
04904
Erase lamp down (2
lamps)
Both of the erasure lamps have
blown out.
Carry out lamp replacement immedi-
ately.
04905
SCB2 communication
error
No ACK was received in
response to an ENQ code in
accordance with the SCB2 com-
munication protocol.
If the error repeats after restart by per-
forming open/close of the front cover,
check the follows.
1) Reoccurrence even after opening
and closing of the door and a restart.
2) Check the connection of the power-
supply connector and the SCB2.
3) Check the voltage level in the SCB2.
4) Con
fi
rm that the SCB2(CN5)-
MCB2(CN4) connectors are con-
nected.
5) Con
fi
rm that the CF card has been
inserted.
6) Replace the CF card and check the
subsequent operation.
7) Replace the SCB2 and con
fi
rm the
subsequent operation.
Содержание REGIUS 190
Страница 7: ...VI REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 01...
Страница 13: ...Blank...
Страница 27: ...xx REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 01...
Страница 28: ...Chap 1 Overview...
Страница 29: ...Blank Page...
Страница 43: ...16 1 3 Layout of Controlling Components REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 01...
Страница 45: ...Blank Page...
Страница 52: ...Chap 2 Disassembly and Reassembly...
Страница 53: ...Blank Page...
Страница 118: ...Chap 3 Maintenance Adjustment...
Страница 119: ......
Страница 153: ...126 3 9 Adjusting the Position of Insertion Guide Switch SW4 REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 01...
Страница 154: ...Chap 4 Troubleshooting...
Страница 155: ......
Страница 194: ...A Appendix...
Страница 195: ......
Страница 218: ...191 A 5 Parts Layout Diagram REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 A 5 2 SCB2 System Control Board...
Страница 219: ...192 A 5 Parts Layout Diagram REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 A 5 3 ADB2 A D Board...
Страница 220: ...0676 55030 B 0412TE...