46
Instruction manual SMV 10 600B – 60 1500B Publ. no. 6196.082 1117, Version 02
Service and maintenance
Radiator coolant level
WARNING
The system is under pressure!
• Open the refill lid (1) on the overflow tank. First, a 1/4 turn
carefully to release any pressure.
• The level should be at the MAX-level on the side of the overflow
tank.
Inspection of fuel level
• Turn the key to position I.
• Wait until the fuel gauge (2) on the instrument panel has stabilised.
• If necessary, fill with the recommended diesel fuel.
WARNING
In order to avoid that air is sucked into the fuel
injection system, the fuel tanks should never be
allowed to run dry. If air enters the fuel system,
the engine will stop and the fuel system must be
bleed.
• Disconnect the ignition.
• Fill as per below.
Filling up fuel
• Open the filler cap placed on the left side of the machine and fill
with the recommended fuel.
• Refit the lid.
• In order to avoid that air is sucked into the fuel injection system,
the fuel tanks should never be allowed to run dry. There should
be about 20-25 litres left in the tank.
Fuel tank capacity, see "Liquid volumes" on page 100.