OPERATION
MACHINE OPERATIONS AND CONTROLS
3-179
Inversion
3
NOTICE
The rock bucket (PC300: if equipped, PC350: standard)
interferes with the arm, so it cannot be turned and used for
shovel operations.
1.
Place the bucket in contact with a flat surface.
REMARK
When removing the pins, place the bucket so that it is in light
contact with the ground.
If the bucket is lowered strongly to the ground, the resistance
will be increased and it will be difficult to remove the pins.
NOTICE
After removing the pins, make sure that mud or sand does
not get on them. Dust seals are fitted at both ends of the
bushings, be careful not to damage them.
2.
Remove the double nut on the stopper bolt for arm pin (A)
and link pin (B), remove the bolt, pull out arm pin (A) and
link pin (B), and then remove the bucket.
3.
After removing the bucket, reverse it.
4.
Align arm (5) with replacement bucket hole (1), then align
link (6) with hole (2), coat pins (A) and (B) with grease, and
install.
Содержание PC350LC-8
Страница 2: ......
Страница 3: ...FOREWORD 11...
Страница 12: ...PRODUCT INFORMATION FOREWORD 1 10 SERVICE METER LOCATION 1 On top of the machine monitor...
Страница 278: ...TROUBLES AND ACTIONS OPERATION 3 214...
Страница 279: ...MAINTENANCE 14 WARNING Please read and make sure that you understand the SAFETY section before reading this section...
Страница 335: ...MAINTENANCE MAINTENANCE PROCEDURE 4 57 6 Boom cylinder foot pin 2 places 7 Boom foot pin 2 places...
Страница 366: ...MAINTENANCE PROCEDURE MAINTENANCE 4 88...
Страница 367: ...SPECIFICATIONS 15...
Страница 371: ...SPECIFICATIONS SPECIFICATIONS 5 5...
Страница 372: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Страница 432: ...SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 60...
Страница 496: ...SPECIFICATIONS HIGH REACH DEMOLITION MANUAL 7 64...
Страница 497: ...INDEX 18...
Страница 498: ...INDEX 8 2...
Страница 501: ...COLOPHON 18...