SYSTem Subsystem
System commands control system functions that are not directly related to output control,
measurement, or status functions. Note that IEEE-488 Common commands also control system
functions such as self-test, saving and recalling states, and others.
SYSTem
:BBR
:EVENt <
"string"
>
Adds an event string into the BBR event log.
:SNAPshot <value>
Captures a data snapshot of the specified length.
:STATus?
Returns the completion status of the snapshot in percent.
:STATe?
Returns true (1) if the Black Box Recorder is logging.
:TIME?
Returns the length of the Black Box Recorder data.
:COMMunicate
:LAN|TCPip:CONTrol?
Returns the initial socket control connection port number.
:RLSTate LOCal|REMote|RWLock
Configures the remote/local state of the instrument.
:DATE <yyyy>,<mm>,<dd>
Sets the date of the system clock.
:ERRor?
Reads and clears one error from the error queue.
:LFRequency?
Returns the power-line reference frequency.
:LFRequency
:MODE AUTO|MAN50|MAN60
Specifies automatic or manual line frequency detection.
:PASSword
:FPANel
:RESet
Resets the front panel lockout password to zero.
:REBoot
Reboots the instrument to its power-on state.
:SECurity
:IMMediate
Clears all user memory and reboots the instrument.
:SIGNal
:DEFine EXPRession<1-8>,
<
"expression"
>
Defines up to eight signal expressions.
:TEMPerature
:AMBient?
Returns the temperature at the air inlet.
:TIME <hh>,<mm>,<ss>
Sets the time of the system clock.
:VERSion?
Returns the SCPI version that the instrument complies
with.
SYSTem:BBR:EVENt <
"string"
>
Adds an event string into the BBR event log. The BBR event log has room for 100,000 events. The
maximum length of the string is 55 characters. Enclose string parameters in single or double quotes.
Parameter
Typical Return
<
"string"
>String program data.
(none)
Enter a message into the BBR data: SYST:BBR:EVEN "Starting BBR data"
Keysight N6900/N7900 Series Operating and Service Guide
270
6 SCPI Programming Reference
Содержание N6900 Series
Страница 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Страница 2: ......
Страница 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Страница 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 90: ...Rack Mounting 2 Installing the Instrument 90 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 289: ...Status Diagram 6 SCPI Programming Reference 289 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 354: ...Cover screws 8 Service and Maintenance 354 Keysight N6900 N7900 Series Operating and Service Guide...