Parameter
Typical Return
(none)
<points>
Returns the number of points in the dwell list: LIST:DWEL:POIN?
[SOURce:]LIST:STEP ONCE|AUTO
[SOURce:]LIST:STEP?
Specifies how the list responds to triggers. ONCE causes the output to remain at the present step until
a trigger advances it to the next step. Triggers that arrive during the dwell time are ignored. AUTO
causes the output to automatically advance to each step, after the receipt of an initial starting trigger.
Steps are paced by the dwell list. As each dwell time elapses, the next step is immediately output.
Parameter
Typical Return
ONCE|AUTO, *RST AUTO
ONCE or AUTO
Specifies the list steps to be paced by trigger signals: LIST:STEP ONCE
[SOURce:]LIST:TERMinate:LAST 0|OFF|1|ON
[SOURce:]LIST:TERMinate:LAST?
Determines the output value when the list terminates. When ON (1), the output voltage or current
remains at the last list step. The value of the last voltage or current list step becomes the IMMediate
value when the list completes. When OFF (0), and also when the list is aborted, the output returns to
the settings that were in effect before the list started.
Parameter
Typical Return
0|OFF|1|ON , *RST OFF
0 or 1
Terminate with the output at the last step value: LIST:TERM:LAST ON
[SOURce:]LIST:TOUTput:BOSTep[:DATA] 0|OFF|1|ON {,0|OFF|1|ON }
[SOURce:]LIST:TOUTput:BOSTep[:DATA]?
[SOURce:]LIST:TOUTput:EOSTep[:DATA] 0|OFF|1|ON {,0|OFF|1|ON }
[SOURce:]LIST:TOUTput:EOSTep[:DATA]?
Specifies which list steps generate a trigger signal at the beginning of step (BOSTep) or end of step
(EOSTep). A trigger is only generated when the state is set to ON. The trigger signal can be used as a
trigger source for measurements and transients of other units, and for digital port pins configured as
trigger outputs.
Parameter
Typical Return
0|OFF|1|ON
0 or 1
To generate triggers at the beginning of the second step of a 3-step list:
LIST:TOUT:BOST OFF,ON,OFF
Keysight N6900/N7900 Series Operating and Service Guide
242
6 SCPI Programming Reference
Содержание N6900 Series
Страница 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Страница 2: ......
Страница 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Страница 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 90: ...Rack Mounting 2 Installing the Instrument 90 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 289: ...Status Diagram 6 SCPI Programming Reference 289 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 354: ...Cover screws 8 Service and Maintenance 354 Keysight N6900 N7900 Series Operating and Service Guide...