![Keysight Technologies N6900 Series Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217184.webp)
Example (300 A load current) You have three 9V units connected in parallel. Two of the units are 1kW
units with a rated current of 100A. The other is a 2kW unit with a rated current of 200A. The load draws
300A of current.
You must first calculate the ideal output current contribution for the 1 kW and the 2 kW units. The ideal
current contribution for the 1 kW unit is calculated as follows:
IOUT
(1KW_IDEAL)
=ILOAD_TOTAL / (NT+N2kW)
IOUT
(1KW_IDEAL)
=300A / (3+1)
IOUT
(1KW_IDEAL)
=75A
The ideal current contribution for a 2 kW unit is calculated as follows:
IOUT
(2KW_IDEAL)
=2(ILOAD_TOTAL) /( NT+N2kW)
IOUT
(2KW_IDEAL)
=2(300A) / (3+1)
IOUT
(2KW_IDEAL)
=150A
where NT= 3, N1KW = 2, and N2kW =1
Note that the total ideal current equals the total load current: 2(75A) + 150A = 300A
You can now use the gain and offset values for three paralleled units of mixed power (G=0.320%;
K=1.08%) to determine the worst-case deviation from the ideal current for each 1 kW unit. Note that
for a mixed power configuration, the equations use I2kW_RATINGfor both the 1kW and the 2kW
calculations.
∆IOUT
(1KW_WORST_CASE)
=±G(IOUT
(1KW_IDEAL)
) ±K(I2kW_RATING)
∆IOUT
(1KW_WORST_CASE)
=±0.32%(75A) ±1.08%(200A)
∆IOUT
(1KW_WORST_CASE)
=±2.4A
Repeat the above step for the 2 kW unit.
∆IOUT
(2KW_WORST_CASE)
=±G(IOUT
(2KW_IDEAL)
) ±K(I2kW_RATING)
∆IOUT
(2KW_WORST_CASE)
=±0.32%(150A) ±1.08%(200A)
∆IOUT
(2KW_WORST_CASE)
=±2.64A
4 Using the Advanced Power System
184
Keysight N6900/N7900 Series Operating and Service Guide
Содержание N6900 Series
Страница 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Страница 2: ......
Страница 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Страница 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 90: ...Rack Mounting 2 Installing the Instrument 90 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 289: ...Status Diagram 6 SCPI Programming Reference 289 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 354: ...Cover screws 8 Service and Maintenance 354 Keysight N6900 N7900 Series Operating and Service Guide...