Operation and Maintenance
7.3.4
ESW Download on a redundant COGE5 Unit plugged in the first Time
The unit ESW (UN ESW) and the network element ESW (NE ESW) can be
downloaded and started on a redundant COGE5 unit using the ECST tools
menu “Software Download …” or via the ECST at the access points AP: /
unit-x, Main - Software and AP: /unit-x/neController, Main - Software.
ESW download on a
redundant COGE5
The instructions below assume
- the ECST accesses the above mentioned access points.
- the active COGE5 unit is plugged in slot 11, the redundant COGE5 unit is
plugged in slot 13.
The following actions must be performed to download and start the
‒ network element ESW, and the
‒ unit ESW.
Download and start the NE
ESW
Proceed as follows:
1. Set up a management connection to the XMC20 network element.
-
Select the user class “manager”. This is necessary to receive the
access rights for downloading ESWs to the units of the NE.
2. Select the AP: /unit-13/neController, i.e. the redundant COGE5 unit.
-
The AP: /unit-13/neController is running in the network element boot-
loader (bco5n_rxx).
3. Open the MF “Main” of the AP: /unit-13/neController and select the tab
“Software”.
-
Select the desired COGE5 NE ESW (co5ne_r2bxx) in the list of
“Software On Element Manager” and click “Download”.
-
Wait until the download is terminated and the ESW appears in the list
“Software On Unit”.
4. In “Configuration” select the downloaded ESW under “Software”.
-
Check that “Software Installation” is set to “Manual Start”.
-
Execute “Apply”.
-
Save the configuration to the NE flash memory: Execute “Save to
NE”.
5. Start the new software.
-
Click the command button “Start Software”. This reboots the redun-
dant control unit.
6. Wait until the unit has booted.
-
The AP: /unit-13/neController is running the NE ESW (co5ne_r2bxx).
-
The AP: /unit-13 is still running in the unit bootloader (bco5u_rxxxx).
Result:
The neController of the redundant COGE5 unit is running the
configured ESW.
Download and start the UN
ESW
Proceed as follows:
1. Select the AP: /unit-13, i.e. the redundant COGE5 unit.
-
The AP: /unit-13 is running in the unit bootloader (bco5u_rxx).