Commissioning

6

Commissioning

This section presents how to configure and bring into operation the COGE5 
unit and its main functions. For operation, i.e. status and maintenance func-
tions refer to section 

7 Operation and Maintenance

 (on page 57).

6.1

Commissioning Prerequisites for COGE5

The following prerequisites must be fulfilled for the commissioning of a 
COGE5 unit:

6.1.1

COGE5 Unit

A COGE5 must be physically plugged in slot 11 of the XMC20 subrack. 
Please make sure the HW fulfils the requirements stated in 

[012] Release 

Note “XMC20 System Release R6B”

.

Please note:

When you power up the COGE5 unit for the first time (from factory default 
settings), all LEDs will be “ON”. This state means that the network element 
bootloader is active but there is no application software (ESW) to launch. 
You will need to install an appropriate ESW.

→ For the installation procedures and the detailed initial connection pro-

cedure please refer to 

[354] Quick Guide “ECST”

.

A redundant COGE5 unit (if required) must be physically plugged in slot 13 
of the XMC20 subrack. This is mandatory if you want to implement core unit 
redundancy. It is not required if you do not want core unit redundancy.

6.1.2

ECST

ECST needs to be installed on a PC, and a management connection from 
the ECST to the XMC20 needs to be up and running. For details about the 
installation and operation of the ECST, please refer to 

[354] Quick Guide 

“ECST”

 and 

[355] User Manual “ECST”

.

The amount and accessibility of operations depend on the user profile with 
which you are logged in. For more information, please refer to 

[323] User 

Guide “Management Communication”

.

Please note:

Ethernet cabling should be connected to both the master and the redundant 
COGE5 if redundancy is implemented.

→ In this case, care must be taken to correctly configure split horizon 

settings in order to avoid broadcast storms.

Содержание co5ne_r2b

Страница 1: ...User Manual COGE5 COGE5 F co5ne_r2b co5un_r2b Control 10 Gb Ethernet switch uplinks sync XMC20...

Страница 2: ...ed in whole or in part or any of its contents dis closed by the recipient to any third party without the prior written agreement of KEYMILE Disclaimer KEYMILE has taken reasonable care in compiling th...

Страница 3: ...9 1 6 Definition of Terms 9 2 Introduction 10 2 1 General 10 2 2 Unit View 12 2 3 Block Diagram 13 3 Specification 14 3 1 Feature Licences 14 3 2 COGE5 Function Overview 15 3 3 COGE5 F Function Overvi...

Страница 4: ...Optical Indicators 57 7 2 Maintenance 59 7 3 Unit and Network Element ESW Download 60 7 4 Setting up Mirror Ports 68 7 5 MPLS TP Status 69 7 6 PTP Status 69 8 User Interface Reference 70 8 1 Introduc...

Страница 5: ...User Manual COGE5 COGE5 F page 5 of 110 KEYMILE December 2015 EN LZTBU 372 144 3 RA 9 3 Product Training 110...

Страница 6: ...COGE5 F right front panel and interface connectors 24 Figure 7 Ethernet link LEDs on the electrical Ethernet interfaces 25 Figure 8 Side view of the subrack including cabling and cable tray 29 Figure...

Страница 7: ...logy Equipment Please refer to the following document 202 Safety Instructions Precautions and safety 1 2 Symbols and Notations This User Manual uses the following symbols CAUTION Non observance could...

Страница 8: ...ed to the SFPs plugged in the COGE5 unit COGE5 interface Parameter Max rating Remarks Optical Gigabit and 10 Gigabit Ethernet Laser class according to EN 60825 1 1 b b As the laser protection class 1...

Страница 9: ...R6B Support of rate limiters on Ethernet ports RSTP and MSTP no longer supported LZTBU 372 144 2 RA March 2015 R6A New PTP feature Support of MPLS TP Quality level mapping tables for synchronous Ether...

Страница 10: ...N switching related functions and layer 2 protocols 358 User Manual MPLS TP XMC20 MPLS TP Transport application Label Edge Router and Label Switch Router functions 314 User Guide TDM Services and Cros...

Страница 11: ...ted in slot 11 by insert ing and configuring a second control unit in slot 13 The details described in this document base on a specific COGE5 or COGE5 F embedded software ESW version For more details...

Страница 12: ...F right unit view Figure 2 COGE5 left and COGE5 F right unit view shows the COGE5 and COGE5 F units with their front panels and interfaces On the front plate are four LEDs for unit and traffic status...

Страница 13: ...ase refer to section 5 Func tional Description on page 31 Figure 3 Block diagram of COGE5 Alarm CPU NE Switching Synchronization Redundancy Control TrunkIF Subtending IF Management IF Optical Alarm in...

Страница 14: ...licences are available for this unit For more information on feature licences please refer to 012 Release Note XMC20 System Release R6B and to 915 Technical Bulletin Feature Licences for XMC20 Table 5...

Страница 15: ...2 2 048 MHz Micro D Sub 120 according to ITU T G 703 or high impedance 1 6 k yes 1500 VRMS r1a Synchronization interface outputs Frequency Connector type Impedance Galvanic isolation 2 2 048 kHz Micro...

Страница 16: ...ith INF 8074 specification SFP complying with SFF 8431 specification r1a Local management port Number of ports Connector type Impedance 10BASE T 100BASE TX 1 RJ 45 100 15 frequency band 1 16 MHz r1a R...

Страница 17: ...or standard Release Table 9 COGE5 Function Overview fault management Feature Rating or standard Release Fault management ITU T X 733 Alarm Reporting r1a Table 10 COGE5 Function Overview equipment fea...

Страница 18: ...manufacturer s data sheets typi cally IEC 60825 1 Class 1 laser product r1a Ambient conditions refer to 201 System Description XMC20 R6B Error free operation up to 60 C ambient tempera ture is only gu...

Страница 19: ...R6B Table 12 COGE5 F Function Overview equipment features Feature Rating or standard Release Mechanical parameters Width of the unit 1 TE 5 08mm Weight of the COGE5 F unit 8 TE 2 slots 1 700 g r1a Un...

Страница 20: ...ware HW and embedded software ESW ver sions are given in 012 Release Note XMC20 System Release R6B For a description of the first ESW download and assignment to the COGE5 unit please refer to 354 Quic...

Страница 21: ...s shown in Figure 5 XMC20 subracks with core unit COGE5 in slot 11 redundant core unit COGE5 in slot 13 All other slots can be equipped with service units SU Please note The COGE5 F units occupy slot...

Страница 22: ...U S U S U S U S U S U S U S U S U S U S U S U S U S U S U S U S U S U Slot 1 Slot 11 Slot 21 S U S U S U S U S U S U S U S U S U S U S U S U S U S U S U S U S U Slot 7 Slot 11 Slot 14 S U S U S U S U...

Страница 23: ...o 012 Release Note XMC20 System Release R6B 4 3 2 Previous ESW Revisions The COGE5 unit with ESW release co5xx_r2b is compatible to the previous XMC20 system release R6A Please refer to 012 Release No...

Страница 24: ...GbE interfaces traffic interfaces Fixing screw Pull out handle with identification label Optical status indications port 5 port 4 port 3 port 2 port 1 Fixing screw Pull out handle R1B 37900374 pin 1 p...

Страница 25: ...Please note SFP modules must be fully MSA Multi Source Agreement compliant SFF 8431 Please note that only KEYMILE s recommended SFP modules should be used in order to guarantee inter working with the...

Страница 26: ...s Then go to Technical Bulletins and open the Supported SFP Trans ceivers document once you have logged in The recommended SFP module types are listed in the above mentioned Technical Bulletin The sel...

Страница 27: ...of category 6 cables Electrical 10BASE T 100BASE TX 1000BASE T ports on COGE5 support auto negotiation with parallel detection Auto Negotiation allows the highest performance mode to be automatically...

Страница 28: ...uplex mode then there is an incon sistent configuration and the side operating in half duplex may experience collisions while transmitting data Please note Ethernet cables can be ordered from KEYMILE...

Страница 29: ...er Guide XMC22 Installation 4 4 7 Cabling with COGE5 Redundancy When using a redundant core unit in slot 13 cabling is different Since the core unit HW is duplicated some of the front connections have...

Страница 30: ...tion Interface on page 38 The ESI inputs are supervised on the active and on the standby COGE5 unit An alarm is raised if an ESI input is only connected to one of the two units Synchronization output...

Страница 31: ...ation The COGE5 front ports are usable as PETS timing sources based on Syn chronous Ethernet or the PTP approach The COGE5 core unit also provides redundancy through 1 1 equipment pro tection when two...

Страница 32: ...anagement Communication 5 1 4 Switching The COGE5 unit provides five external Ethernet interfaces acting as XMC20 Switch ports three electrical GbE for electrical GbE and two SFP SFP modules for optic...

Страница 33: ...l traffic in the field Note that with sequential MAC addresses as they are used in stress or acceptance test scenarios the maximum value can be reduced VLAN VLAN support 802 1Q Yes VLAN no 4089 1 4089...

Страница 34: ...itch devices being part of the XMC20 Switch all transport VLAN tagged frames The COGE5 internal ports connecting Ethernet switch devices not being part of the XMC20 Switch are handled as an external B...

Страница 35: ...tion Functions The link protection function MPLS TP tunnel protection is a feature of the MPLS TP Transport function of the XMC20 Switch Please refer to 358 User Manual MPLS TP 5 1 6 Security Features...

Страница 36: ...Transport VPWS service the port type of traffic ports must be configured to PWAC i e Pseudo Wire Access Circuit or to MPLS TP i e MPLS TP uplink port No further port configuration is required Please n...

Страница 37: ...t SFP modules refer to section 4 4 2 SFP 10GbE optical Modules and Cables on page 25 For details about SFP modules refer to section 4 4 3 SFP GbE optical Modules and Cables on page 26 The selection of...

Страница 38: ...note The switch device on the redundant COGE5 unit participates in the XMC20 Switch 5 2 2 Management Ports Please refer to section 5 1 3 Management Traffic and Routing on page 32 5 2 3 Mirror Ports A...

Страница 39: ...uelched The impedance of an active output interface is 120 Ohm the impedance of a squelched or disabled output on the standby COGE5 unit is high 5 2 5 Backplane Interfaces 5 2 5 1 1GbE double Star Slo...

Страница 40: ...N is used for the management communication between the core unit and service units within the subrack The main functions of the ICN bus are Service unit configuration and fault management Configuratio...

Страница 41: ...1 1 equipment protection for the core unit by installing a redundant core unit in slot 13 of the XMC25 or XMC23 subrack For the redundant core unit installation procedure please refer to section 7 3...

Страница 42: ...he synchronization parameters concerning the XMC20 system are config ured with ECST at the AP ne Configuration For more details refer to 314 User Guide TDM Services and Cross Connections in XMC20 At C...

Страница 43: ...usage of ESMC is configurable with a configu ration parameter at the AP unit x port a Configuration SyncE The received and transmitted QL values can be adapted using the Input Mapping Table and Output...

Страница 44: ...rbitrarily selects one of the ports as master The alarm CLKMIS Clock Mismatch is activated on the master port Timing transfer is only possible in one direction 5 4 3 Precision Time Protocol The COGE5...

Страница 45: ...is is the for ward path Master to Slave The PTP quality level information in reverse direction Slave to Mas ter is not applicable Risk of operating trouble When using the Hybrid or Pure Hybrid PTP mod...

Страница 46: ...5 AP unit x port y Configuration PTP PTP Mode Ordinary Boundary Clock COGE5 AP unit x port y Configuration PTP Role Slave for ports with a fixed Slave role Master for ports with a fixed Master role Ma...

Страница 47: ...P Clock Type Boundary Clock Ordinary Clock preferred COGE5 AP unit x port y Configuration PTP PTP Mode Ordinary Boundary Clock COGE5 AP unit x port y Configuration PTP Role Slave preferred Master Or S...

Страница 48: ...synchronize the PETS to a Transparent Clock connect a Transparent Clock Master to an additional COGE5 front port con figured as Ordinary Boundary Clock Slave Figure 15 PTP Transparent Clock For a Tran...

Страница 49: ...ster Or Slave for ports for which the role can change when the synchronization path direction changes COGE5 AP unit x port y Overview Port Type Usage CVP ECST Switching view Switching Bridging bridge...

Страница 50: ...ESW to launch You will need to install an appropriate ESW For the installation procedures and the detailed initial connection pro cedure please refer to 354 Quick Guide ECST A redundant COGE5 unit if...

Страница 51: ...fer to 355 User Manual ECST For all management connection related topics please refer to 323 User Guide Management Communication For a specific description of the ESW download and assignment to a COGE...

Страница 52: ...the network element bootloader no ESW is installed You need to install valid ESW on the COGE5 unit in slot 11 If you implement core unit redundancy you need to install the identical ESW on the COGE5 u...

Страница 53: ...VLANs with VLAN ID 100 and 101 Configure the scheduling pro file Proceed as follows 1 Select the Tree View of the ECST 2 Navigate to the scheduling profile parameters AP ne Configuration QoS Schedulin...

Страница 54: ...s 6 Execute Apply Result The bridge is completely configured Configure the bridge port parameters Proceed as follows 1 Select the Switching view of the ECST 2 Navigate to the port parameters of bridge...

Страница 55: ...he bridge 1 are completely configured Activation Proceed as follows 1 Select the Tree View of the ECST 2 Navigate to the port parameters AP unit x port 5 Main General 3 Set the administrative state of...

Страница 56: ...358 User Manual MPLS TP 6 5 Commissioning the PTP synchronization The management functions for the commissioning of the PTP synchroniza tion are located in the ECST tab Tree View at the following acce...

Страница 57: ...to section 6 Commissioning on page 50 7 1 Unit Optical Indicators The COGE5 unit has four LED optical indicators showing information about the unit traffic status and lock state The following figure...

Страница 58: ...he COGE5 can only provide the point to point type of management communication This means that only the Ethernet local management port will allow a direct connection for initial commissioning Recovery...

Страница 59: ...read inventory data from the COGE5 unit via the ECST at the following access points AP unit x Main Inventory for unit related information and AP unit x neController Main Inventory for NE control proc...

Страница 60: ...AP unit x Main Software and AP unit x neController Main Software ESW download for the unit and the network element The instructions below assume the ECST accesses the above mentioned access points th...

Страница 61: ...configuration to the NE flash memory Execute Save to NE 11 Start the new unit software In the MF Main of the AP unit 11 i e the COGE5 unit click the command button Start Software This reboots the unit...

Страница 62: ...NE 2 Select the AP unit 11 i e the COGE5 unit The AP unit 11 is running with the unit ESW co5un_rxxxx 3 Open the MF Main and select the tab Software Select the new COGE5 UN ESW co5un_r2bxx in the lis...

Страница 63: ...E 2 Select the AP unit 11 neController The AP unit 11 neController is running with the network element ESW co5ne_rxxxx 3 Open the MF Main and select the tab Software Select the new COGE5 NE ESW co5ne_...

Страница 64: ...ESWs to the units of the NE 2 Select the AP unit 13 neController i e the redundant COGE5 unit The AP unit 13 neController is running in the network element boot loader bco5n_rxx 3 Open the MF Main of...

Страница 65: ...re unit to make it available for commissioning The redundant COGE5 is now ready for configuration The working COGE5 unit in slot 11 is the active unit The redundant COGE5 unit in slot 13 is the standb...

Страница 66: ...7 3 6 Set the COGE5 Unit into the Unit Boot loader on page 66 7 3 6 Set the COGE5 Unit into the Unit Bootloader Please note Setting the active COGE5 unit into the bootloader while there is a standby...

Страница 67: ...aded ESW under Software Check that Software Installation is set to Manual Start 7 Execute Apply Please note When the COGE5 unit is running in the network element bootloader the Save to NE command is e...

Страница 68: ...the ECST 2 Navigate to the COGE5 port parameters AP unit 11 port 5 Overview Port Type 3 Set the port type for the mirror port Usage Analyzer 4 Execute Apply Result The port type is configured Configur...

Страница 69: ...MPLS TP For a description of this functionality please refer to 358 User Manual MPLS TP 7 6 PTP Status The management functions for the operation of the PTP synchronization functions are located in t...

Страница 70: ...in 302 User Guide XMC25 XMC23 XMC22 8 1 Introduction Below you find a detailed description of all the configuration parameters and operations belonging to the managed objects model MOM for the COGE5 c...

Страница 71: ...gement of the Ethernet front ports The AP port a includes both 1000BASE X 10000BASE R SFP Ethernet ports port 1 and port 2 and electrical 10 100 1000BASE T Ether net ports port 3 to port 5 The detaile...

Страница 72: ...of each AP In the tables of the sections below the parameter default values for proper ties are underlined Please note For better legibility of numbers in this user guide inverted commas are used when...

Страница 73: ...operated in the XMC20 8 2 1 AP unit x Overview For a description of the Overview Alarms Overview Mirroring Overview Port Type and Overview Statistics management functions please refer to 302 User Gui...

Страница 74: ...t general message Clock Domain 0 255 A domain consists of one or more PTP devices commu nicating with each other 0 is the default domain Table 20 AP unit x Fault Management ID Fault Cause Event Type T...

Страница 75: ...r version NSW No Application Soft ware Equipment Alarm Major There is no application ESW installed on the unit or the application ESW has not yet finished its boot process UIC Unit Incompatible Equipm...

Страница 76: ...al ports port 3 port 4 and port 5 The SFP SFP based ports provide SFP cages for the implementation of SFP SFP modules The supported speeds are 1000 Mbit s 1 Gbit s and 10 000 Mbit s 10 Gbit s accordin...

Страница 77: ...eral Operation Name Parameter Name Range Descriptions Details Interface Status Admin Status Up Select Up to bring the port into service Down Select Down to take the port out of service Oper Status Up...

Страница 78: ...should correspond to the Type Status parameter Type Status None No SFP module is plugged Detected SFP module types Shows the type of the plugged SFP module Equipment Inven tory Equipment State Ok Equ...

Страница 79: ...e Parameter Name Range Descriptions Details MAC Address 00 00 00 00 00 00 ff ff ff ff ff ff Shows the physical MAC address of this port This parameter is read only Port Speed 10 Mbit s Shows the port...

Страница 80: ...ex 1000BaseT FD 1 Gbit s full duplex 1000Base xx FD 1 Gbit s full duplex for SFP modules only The xx string designates the SFP type e g SX 10GigBase xx 10 Gbit s full duplex for SFP modules only The x...

Страница 81: ...peration Name Parameter Name Range Descriptions Details Synchronization Method None Do not use a synchronization method ESMC Use the Ethernet Synchronization Message Channel ESMC for the transport of...

Страница 82: ...TP 2 PTP 3 PTP 4 Internal Usage NA No synchronization method has been selected CanBeUsed Transmit the QL value of the selected synchroni zation source DoNotUse Transmit the QL value 15 i e indicating...

Страница 83: ...00BASE TX half duplex mode can be used for synchronous Ethernet The half duplex mode applies only for the layer 2 and above the phys ical layer operates in full duplex mode Please note For more inform...

Страница 84: ...t The PTP port cannot be used as PETS synchro nization source The master role is not supported if the PTP clock type is configured to Ordinary Clock Master Or Slave The PTP port is a slave or a master...

Страница 85: ...gured at the AP ne Configuration PTP 1 Message Per Second 2 Messages Per Second 4 Messages Per Second 8 Messages Per Second 16 Messages Per Second 32 Messages Per Second 64 Messages Per Second Delay 1...

Страница 86: ...the a description of the general aspects of the Fault Management Status and Fault Management Configuration management functions please refer to 302 User Guide XMC25 XMC23 XMC22 The following table li...

Страница 87: ...alue is 15 or the port operational state is down 1 14 The received SSM value is 15 Transmitted QL Unknown The synchronization method None has been configured The port transmits no ESMC messages Do Not...

Страница 88: ...is 15 or the port opera tional state is down or the port is a transparent port Unknown The received PTP QL is 0 Clock Class 82 1 14 The received QL value is 15 Transmitted QL Do Not Use The Do Not Us...

Страница 89: ...ions in XMC20 Clock Accuracy Unknown Characterizes a clock for the purpose of the best master clock BMC algorithm See table 6 of IEEE 1588 2008 25 ns 10 s Worse than 10 s Offset Scaled Log Variance 0...

Страница 90: ...state is currently unknown Disabled The stream has been disabled Grandmaster Operating on a clock with a clock class 127 and is currently grandmaster in the network Master Operating as a master on a...

Страница 91: ...Counters RX Octets 0 264 1 Number of ingress octets RX Unicast Packets 0 264 1 Number of ingress unicast packets RX Multicast Packets 0 264 1 Number of ingress multicast packets RX Broadcast Packets 0...

Страница 92: ...User Manual COGE5 COGE5 F page 92 of 110 KEYMILE December 2015 EN LZTBU 372 144 3 RA 110 User Interface Reference 8 3 6 2 AP unit x port a Statistics Ethernet...

Страница 93: ...ber of egress frames for which the first transmission attempt is delayed because the medium is busy Collisions 0 232 1 Number of estimated collisions Late Collisions 0 232 1 Number of times that a col...

Страница 94: ...t type of the Ethernet port is configured to PWAC or to CVP First configure the port type to PWAC or to CVP For a description of the QoS Rate Limiting management function please refer to 302 User Guid...

Страница 95: ...gement functions please refer to 302 User Guide XMC25 XMC23 XMC22 The following table lists the fault causes of the current AP Table 32 AP unit x port a mau Fault Management ID Fault Cause Event Type...

Страница 96: ...ult Management For the a description of the general aspects of the Fault Management Status and Fault Management Configuration management functions please refer to 302 User Guide XMC25 XMC23 XMC22 The...

Страница 97: ...unit is not com patible with the unit configuration stored in the database You may need to upgrade or downgrade the ESW or re create the configuration with the cur rently running ESW SWIN Software In...

Страница 98: ...port is given a PETS clock prior ity other than Disabled For more information please refer to 314 User Guide TDM Services and Cross Connections in XMC20 8 6 3 AP unit x neController esi y Fault Manag...

Страница 99: ...LE December 2015 EN LZTBU 372 144 3 RA 110 User Interface Reference 8 7 AP unit x neController localManagementPort For a description of the management functions of the local management port please ref...

Страница 100: ...ew Statistics management functions please refer to 302 User Guide XMC25 XMC23 XMC22 Please note The Port Type tab is only available if any of the internal ports is connected to an Ethernet stand alone...

Страница 101: ...s only available on the redundant core unit The backplane port is a 1GbE electrical port The speed of the port is fixed The iport 11 connecting the working core unit is only used if the working core u...

Страница 102: ...2 2 AP unit x iports iport b Main Physical Table 35 AP unit x iports iport b Main General Operation Name Parameter Name Range Descriptions Details Interface Status Admin Status Up Select Up to bring t...

Страница 103: ...0 000 Mbit s The internal Ethernet port is not operational MTU 1978 9 194 Octets Maximum Transmission Unit i e maximum IP packet size The MTU size is calculated including the IP headers Speed And Dupl...

Страница 104: ...Details RX Counters RX Octets 0 264 1 Number of ingress octets RX Unicast Packets 0 264 1 Number of ingress unicast packets RX Multicast Packets 0 264 1 Number of ingress multicast packets RX Broadca...

Страница 105: ...User Manual COGE5 COGE5 F page 105 of 110 KEYMILE December 2015 EN LZTBU 372 144 3 RA 110 User Interface Reference 8 9 3 2 AP unit x iports iport b Statistics Ethernet...

Страница 106: ...Number of egress frames for which the first transmission attempt is delayed because the medium is busy Collisions 0 232 1 Number of estimated collisions Late Collisions 0 232 1 Number of times that a...

Страница 107: ...of the Ethernet port is configured to PWAC or to CVP First configure the port type to PWAC or to CVP For a description of the QoS Rate Limiting management function please refer to 302 User Guide XMC25...

Страница 108: ...t x iports iport b mau 8 10 1 AP unit x iports iport b mau Overview For a description of the Overview Alarms management function please refer to 302 User Guide XMC25 XMC23 XMC22 8 10 2 AP unit x iport...

Страница 109: ...document collection Please note For the HTML based documentation site there are no interdocument hyper links realized yet Please find the required document via the navigation tree on the left 012 Rel...

Страница 110: ...r XMC20 9 2 Technical Support Please refer to the KEYMILE Extranet via http www keymile com for sup port contact information 9 3 Product Training Training courses are available for a wide range of KEY...

Отзывы: