Commissioning
6.2
First ESW Download to a COGE5 Unit
Risk of operating trouble!
An ESW installation may perform also a firmware upgrade which will take
about 30 s. During the firmware upgrade the TRAFFIC LED blinks with 5 Hz.
→ Do NOT disrupt power during this upgrade procedure!
When inserting a COGE5 unit the first time into a XMC20 subrack the unit is
running in the network element bootloader, no ESW is installed.
You need to install valid ESW on the COGE5 unit in slot 11. If you implement
core unit redundancy, you need to install the identical ESW on the COGE5
units in both slot 11 and slot 13.
Note that you have to install two ESW, one for the unit management and one
for the network element management:
• The unit ESW (co5un_r2bxx) is installed at the AP: /unit-x.
• The NE ESW (co5ne_r2bxx) is installed at the AP: /unit-x/neController.
Please make sure the ESW version fulfils the requirements stated in
Release Note “XMC20 System Release R6B”
.
For the first ESW installation procedure please refer to