User Manual
COGE5, COGE5-F
page 79 of 110
© KEYMILE December 2015
EN/LZTBU 372 144/3 RA
110
User Interface Reference
8.3.2.3
AP: / unit-x / port-a, Main – Physical
.
Status
Module Tempera-
ture
°C
SFP module temperature, displayed in °C.
Supply Voltage
mV
SFP supply voltage, displayed in mV.
TX Bias Current
uA
SFP bias current, displayed in μA.
TX Output Power
dBm
Optical power at the transmit interface, displayed
in dBm.
RX Input Power
dBm
Optical power at the receive interface, displayed
in dBm.
Table 22:
AP: / unit-x / port-a, Main – SFP (continued)
Operation Name
Parameter Name Range
Descriptions / Details
Table 23:
AP: / unit-x / port-a, Main – Physical
Operation Name
Parameter Name Range
Descriptions / Details
MAC Address
00:00:00:00:00:00 …
ff:ff:ff:ff:ff:ff
Shows the physical (MAC) address of this port.
This parameter is read-only.
Port Speed
10 Mbit/s
Shows the port speed.
This parameter is read-only.
100 Mbit/s
1000 Mbit/s
10 Gbit/s
MTU
64 … 1’578 … 9’194
Octets,
step 2 Octets
Maximum Transmission Unit, i.e. maximum IP
packet size.
The MTU size is calculated including the IP
headers.
Speed And Duplex
Admin
Auto
Autonegotiation
10BaseT HD
10 Mbit/s, half duplex
10BaseT FD
10 Mbit/s, full duplex
100BaseTX HD
100 Mbit/s, half duplex
100BaseTX FD
100 Mbit/s, full duplex
1000BaseT FD
1 Gbit/s, full duplex
1000Base<xx> FD
1 Gbit/s, full duplex (for SFP modules only).
The <xx> string designates the SFP type, e.g.
SX.
10GigBase<xx>
10 Gbit/s, full duplex (for SFP+ modules only).
The <xx> string designates the SFP type, e.g.
LR.