BHK-MG 1/2 (OPR) 030916
A-1
APPENDIX A - IEEE 488.2 COMMAND/QUERY DEFINITIONS
A.1
INTRODUCTION
This appendix defines the IEEE 488.2 commands and queries used with the BHK-MG 40W Power
Supply These commands and queries are preceded by an asterisk (*) and are defined and
explained in Figures A-1 through A-14, arranged in alphabetical order. Table A-1 provides a quick
reference of all IEEE 488.2 commands and queries supported in the BHK-MG 40W Power Supply.
A.2
*CLS — CLEAR STATUS COMMAND
*CLS
Syntax:
*CLS
Description:
Clears status data.
Clears the following registers without affecting the corresponding Enable Regis-
ters: Standard Event Status Register (ESR), Operation Status Event Register, Questionable Status
Event Register, and Status Byte Register (STB). Also clears the Error Queue. Related commands:
*OPC, *OPC?. (See example, Figure A-1.)
A.3
*ESE — STANDARD EVENT STATUS ENABLE COMMAND
*ESE
Syntax
:
*ESE <integer> where <integer> = positive whole number: 0 to 255 per Table A-2.
Default Value: 0
Description:
This command programs the standard Event Status Enable register bits.
The contents function
as a mask to determine which events of the Event Status Register (ESR) are allowed to set the ESB
(Event Summary Bit) of the Status Byte Register. Enables the Standard events to be summarized in
the Status Byte register (1 = set = enable function, 0 = reset = disable function). All of the enabled
events of the standard Event Status Enable register are logically ORed to cause ESB (bit 5) of the Sta-
tus Byte Register to be set (1 = set = enable, 0 = reset = disable)
.
(See example, Figure A-1.)
A.4
*ESE? — STANDARD EVENT STATUS ENABLE QUERY
*ESE?
Syntax
:
*ESE?
Return value: Integer> value per Table A-2.
Description:
Returns the mask stored in the Standard Event Status Enable Register.
Contents of Standard
Event Status Enable register (*ESE) determine which bits of Standard Event Status register (*ESR)
are enabled, allowing them to be summarized in the Status Byte register (*STB). All of the enabled
TABLE A-1. IEEE 488.2 COMMAND/QUERY INDEX
COMMAND
PAR.
COMMAND
PAR.
*CLS
A.2
*RST
A.10
*ESE, ?
A.3, A.4
*SAV
A.11
*ESR?
A.5
*SRE, ?
A.12, A.13
*IDN?
A.6
*STB?
A.14
*OPC, ?
A.7, A.8
*TRG
A.15
*RCL
A.9
*TST?
A.16
TABLE A-2. STANDARD EVENT STATUS ENABLE REGISTER AND
STANDARD EVENT STATUS REGISTER BITS
CONDITION
PON NU
CME
EXE
DDE
QUE
NU
OPC
BIT
7
6
5
4
3
2
1
0
VALUE
128
64
32
16
8
4
2
1
PON
Power On
NU
(Not Used)
CME
Command Error
EXE
Execution Error
DDE
Device Dependent Error
QUE
Query Error
OPC
Operation Complete
Содержание BHK-MG Series
Страница 2: ......
Страница 6: ......
Страница 16: ......
Страница 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Страница 24: ...1 6 BHK 1 2 MG OPR 030916 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 25: ...BHK 1 2 MG OPR 030916 1 7 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Страница 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Страница 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Страница 108: ...3 62 BHK 1 2 MG 030916 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION Eo is the output voltage of the power assembly...
Страница 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Страница 150: ......