1-10
BHK-1/2-MG (OPR) 030916
FIGURE 1-4. CONNECTOR A2J5 LOCATION
1.4.4
OVERVOLTAGE/OVERCURRENT PROTECTION
Overvoltage and Overcurrent protection values can be individually programmed. The range for
overvoltage and overcurrent values are 0 to 1.1 x E
O
max, 0 to 1.1 x I
O
max. If the output volt-
age/current is maintained at or above the overvoltage/overcurrent protection value for more
than 9ms, the protection circuit cuts the pass element off, discharges the output capacitor, trips
the POWER circuit breaker to OFF and sends a flag on a dedicated line (status port connector).
The default values are 1.1 x E
O
max for overvoltage protection, and 1.1 x I
O
max for overcurrent
protection. Refer to PAR. 3.2.10 for more information.
1.4.5
USER-DEFINED VOLTAGE/CURRENT LIMITS
The BHK-MG 40W Power Supply can be programmed not to exceed user-defined values that
can be lower than the maximum values. For example, the BHK 500-80MG, which has maximum
output values of 500V d-c, 0.08A d-c, can be limited to 100V d-c, 0.04A d-c for working with cir-
cuitry that might be damaged by higher levels. Once the limits are set, the power supply
becomes, in effect a 100V d-c, 0.04A d-c supply and values exceeding the limit values will not
be accepted. Refer to PAR. 3.2.11 for more information.
1.4.6
NONVOLATILE STORAGE OF PROGRAMMED SEQUENCES OR ACTIVE SETTINGS
The BHK-MG 40W Power Supply contains 40 memory locations that can be used either to pre-
program a sequence of output values or to store active settings. For programming sequences
each memory location accommodates six parameters: output voltage, output current, overvolt-
age, overcurrent, time (how long the parameters are in effect) and the next address in the
sequence. Values are stored in the nonvolatile memory, and are retained when the unit is turned
off. Refer to PAR. 3.2.15 for more information.
Содержание BHK-MG Series
Страница 2: ......
Страница 6: ......
Страница 16: ......
Страница 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Страница 24: ...1 6 BHK 1 2 MG OPR 030916 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 25: ...BHK 1 2 MG OPR 030916 1 7 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Страница 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Страница 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Страница 108: ...3 62 BHK 1 2 MG 030916 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION Eo is the output voltage of the power assembly...
Страница 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Страница 150: ......