3-2
BHK-1/2-MG 030916
3.2.1.4
KEYPAD FUNCTIONS
Keypad functions are listed in Table 3-2. Six keys have dual functions, depending on whether
the power supply is in command entry status (waiting for a command to be entered), or data
entry status (waiting for a number to be entered). Command entry status is indicated by a blink-
ing colon
(:_:_:)
and data entry status is indicated by a blinking equal sign
(=_=_=)
.
NOTE: Keys with dual functions are labeled with both a command and a number. The com-
mand label is referred to when the unit is in
(:_:_:)
command entry status; the num-
ber is referred to when the unit is in
(=_=_=)
data entry status.
TABLE 3-1. LCD MESSAGES
LOCATION
MESSAGE
DESCRIPTION
Top left
Loc/Rem
Digital control status: either Remote or Local
Top middle
SINK
Shows that the unit is in sink mode and is absorbing energy either
from the load or the internal output capacitor. The sink current is
model-dependent and appears on the second line of the display pre-
ceded by a minus (–) sign.
top right
OFF/CV/CC
Off/Constant voltage mode/constant current mode
Bottom
left:
in command entry
n.nV
Actual output voltage
In data entry
(parameter)
e.g. OVset if OV SET key was pressed.
Bottom middle:
(:_:_:)
Command entry status
Top or Bottom middle:
(=_=_=)
Data entry status
Bottom
right:
in command entry
n.n mA
Actual output current.
In data entry
n.n V or n.n mA
Present programmed value of parameter, replaced by data entered.
(–)
Minus sign Indicates current absorbed either from the load or dis-
charge of the internal output capacitor.
TABLE 3-2. KEY FUNCTIONS
KEY
POWER SUPPLY
STATUS ACTIVE
DESCRIPTION
REFERENCE
PARAGRAPH
OUTPUT
ON/OFF
Command Entry
If top line of LCD reads OFF, press to enable the output. If output is on,
press to disable the output controlled.
3.2.7
V SET
Command Entry
Press to set output voltage. After V SET is pressed, previous setting is dis-
played. Data entry required to enter new value of output voltage; press
ENTER to accept displayed value.
3.2.9
I SET
Command Entry
Press to set output current. After I SET is pressed, previous setting is dis-
played. Data entry required to enter new value of output current; press
ENTER to accept displayed value.
3.2.9
LOCAL
Command Entry
If the power supply is in remote mode, keypad is disabled except for
LOCAL key. Press to enable keypad. If LCD reads KEYPAD LOCKED, the
LOCAL key is also disabled and can only be unlocked by remote opera-
tion.
3.2.4, B.82
RESET
Command Entry
Press to restore the power on default values: CV mode, output voltage
= 0, output current = value chosen from the POWER-UP OR RESET
CURRENT submenu, overvoltage and overcurrent to 1.1 x nominal value.
3.2.8
Содержание BHK-MG Series
Страница 2: ......
Страница 6: ......
Страница 16: ......
Страница 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Страница 24: ...1 6 BHK 1 2 MG OPR 030916 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 25: ...BHK 1 2 MG OPR 030916 1 7 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Страница 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Страница 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Страница 108: ...3 62 BHK 1 2 MG 030916 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION Eo is the output voltage of the power assembly...
Страница 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Страница 150: ......