BHK-MG 1/2 (OPR) 030916
B-19
B.83
SYSTem:KLOCk? QUERY
SYST:KLOC?
Syntax
:
Short Form: SYST:KLOC?
Long Form: SYSTem:KLOCk?
Return Value: <int_value> 0 or 1
Description:
Identifies whether keypad is locked or unlocked.
0 = keypad unlocked, local operation possible by
pressing LOCAL key. 1 = keypad locked, LOCAL key disabled, only remote operation possible.
Related Commands: SYST:KLOCK. (See example, Figure B-7.)
FIGURE B-7. USING SYSTEM COMMANDS AND QUERIES
B.84
SYSTem:PASSword:CENable COMMAND
SYST:PASS:CEN
Syntax
:
Short Form: SYST:PASS:CEN <val>
Long Form: SYSTem:PASSword:CENable <val>
Description: Sets the password enable state if the value matches the current password. This command allows
other commands such as all the calibration commands to operate.
B.85
SYSTem:PASSword:CDISable COMMAND
SYST:PASS:CDIS
Syntax
:
Short Form: SYST:PASS:CDIS <val>
Long Form: SYSTem:PASSword:CDISable <val>
Description: Clears the password enable state if the value matches the current password.
B.86
SYSTem:PASSword:NEW COMMAND
SYST:PASS:NEW
Syntax
:
Short Form: SYST:PASS:NEW <old password>,<new password>
Long Form: SYSTem:PASSword:NEW <old password>,<new password>
Description:
Establishes new password.
The old (current) password is checked, then the replaced by the new
password. (See PAR. 3.3.5.2 and Figure 3-2 for special programming considerations.)
B.87
SYSTem:PASSword:STATe? QUERY
SYST:PASS:STAT?
Syntax
:
Short Form: SYST:PASS:STAT?
Long Form: SYSTem:PASSword:STATe?
Return Value: <int_value> 0 or 1
Description: Returns a 1 if the password state is enabled or a 0 if it is disabled.
B.88
SYSTem:SECurity:IMMediate COMMAND
SYST:SEC:IMM
Syntax
:
Short Form: SYST:SEC:IMM
Long Form: SYSTem:SECurity:IMMediate
Description: Initializes all NVRAM variables to factory defaults. All memory steps are set to 0 volts, minimum cur-
rent, overvoltage and overcurrent are set to Eomax+10% and Iomax+10%, time value is set to 0.01
Sec. It also initializes the power -up state to have DC Output Control off (see PAR 3.2.7.4). The cali-
bration password is reset per Table 4-3. (See PAR. 3.3.5.2 and Figure 3-2 for special programming
considerations.)
SYST:VERS?
Returns 2003.0.
SYST:KLOC ON
keypad locked, only remote control possible.
SYST:KLOC?
Returns 1 indicating keypad locked.
SYST:KLOC OFF
keypad unlocked, pressing LOCAL key allows Local mode
operation.
SYST:KLOC?
Returns 0 indicating keypad unlocked.
Содержание BHK-MG Series
Страница 2: ......
Страница 6: ......
Страница 16: ......
Страница 18: ...xii BHK MG030916 FIGURE 1 1 BHK MG 40W SERIES PROGRAMMABLE POWER SUPPLY...
Страница 24: ...1 6 BHK 1 2 MG OPR 030916 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Страница 25: ...BHK 1 2 MG OPR 030916 1 7 FIGURE 1 2 BHK 40W SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Страница 26: ...1 8 BHK 1 2 MG OPR 030916 FIGURE 1 3 RA 24 RACK ADAPTER WITH TWO 1 2 RACK BHK MG 40W UNITS...
Страница 35: ...BHK 1 2 MG SERIES 030916 2 3 FIGURE 2 2 BHK MG SERIES REAR PANEL CONTROLS AND CONNECTIONS...
Страница 100: ...3 54 BHK 1 2 MG 030916 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION...
Страница 108: ...3 62 BHK 1 2 MG 030916 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION Eo is the output voltage of the power assembly...
Страница 113: ...BHK 1 2 MG 030916 3 67 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION...
Страница 150: ......