ALARM When any ALARM display, will light up.
AL 1000
EXPLANATION
HYD.PRESSURE AL
HYD.OIL LEVEL LOW
TABLE FILTER PRESSURE AL
SPINDLE COOLANT MOTOR AL
TABLE CYCLE MOTOR AL
COOLANT TANK LEVEL LOW
COOLANT&FILTER MOTOR OVERLOAD
CTS MOTOR OVERLOAD
CHIP CONVEYOR MOTOR OVERLOAD
GEAR LUBE TANK LEVEL LOW
TABLE FILTER AL
AL 1001
AL 1002
AL 1003
AL 1004
AL 1005
AL 1006
AL 1007
AL 1008
AL 1009
AL 1010
AL 1011
A0.0
A0.1
A0.2
A0.3
A0.4
A0.5
A0.6
A0.7
A1.0
A1.1
A1.2
A1.3
TABLE/GEAR MOTOR PRESSURE AL
Check pressure switch and circuit. X8.5
Check hydraulic oil, level switch and circuit. X8.6
Check pressure switch and circuit. X8.2
Check pressure switch signal and circuit. X8.2
Check pressure switch signal and circuit. X8.2
Check pressure switch and circuit. X8.3
Check , level switch and circuit. X8.2
Check tank oil level switch and circuit. X5.5
Check motor, pressure switch and circuit. X3.2
Check motor, pressure switch and circuit. X3.3
Check chip motor,overload switch and circuit. X3.4
Check oil tank level switch and circuit. X8.2