R AD AR
86
7. Troubleshooting
7.1 Troubleshooting for spindle table
(1)
(2)
Spindle table unable to turn:
The related programs appeared warning signals check the program for errors
according to the normal steps to correct the errors.
Spindle table motor overheating:
Confirm the motor loading, change the program or reduce the spindle speed.
7.2 Troubleshooting for Z-axis
(1)
(2)
The grip force reduced of Z-axis :
The hydraulic pressure of Z-axis is insufficient, check the oil pressure gauge,
and adjust the pressure to the standard value.
Collision of Z-axis:
Remove the locks of accessories on Z-axis , such as tool and tool block.
a.
Re-determinate the accuracy of the work-piece and Z-axis , as in the Z-axis
b.
direction, move the indicator to determine the axis parallel, if the deflection is more
than 0.02mm, this step must be repeated.
When the roundness of work-piece is more than 0.01mm/150mm, Z-axis must be
re-calibrated.