When selecting the installation location,
consider the following points:
Ventilation:
The heat generated within the receiver
can be dissipated from the following sides
of the casing: Bottom, left, right and top.
When selecting the installation location,
make sure that these sides are not
obstructed or covered. If the unit is operated
continuously with insuf
fi
cient ventilation,
this can negatively affect the length
of its working life!
The four screw sockets provided (see diagram below) allow you to install the receiver not only resting
on a shelf but also to
fi
x it there or in other positions.
When selecting the installation location, take care that it conforms to the
instructions in the section “Safety Instructions”!
Connections and fusing of the unit:
All connection cables for connection to the receiver (including the infra-red sensor) are connected at the
rear of the unit (see also the item “Connection example” in this section). When selecting the installation
location, allow suf
fi
cient clearance at the rear of the unit for these cables and their plugs.
On the left hand side of the receiver viewed from the front there is a fuse inserted from the outside.
This fuse (for the type, see the section “Important Information”) should be accessible even after the unit
has been installed, so that it can easily be exchanged if required.
The unit monitors its temperature in operation. Premature failure of the unit due
to continuous operation at temperatures higher than the recommended operating
temperature as a result of insuf
fi
cient ventilation does not constitute grounds for a
claim under warranty/guarantee.
Removing the blanking plugs:
When the unit is delivered, the screw sockets are
covered with blanking plugs. These can be pushed
out, using the screws supplied (working upwards
from below, see diagram on the right).
Minimum
clearance
Maintain a clearance of at least 20 cm above or below the unit, 2 cm to either side and 5 cm behind it,
to allow unobstructed dissipation of the heat generated.
20 cm
2 cm
2 cm
5 cm
5 cm
Содержание UFS 940sw
Страница 1: ...Operating manual Englisch UFS 940sw...
Страница 89: ...89 Recording Archive Play Back Edit Recordings...
Страница 122: ...122 Overvoltage protection KAZ 11 KAZ 12 Technical Appendix Sat IF Sat IF Sat IF...
Страница 123: ...123 Overvoltage protection KAZ 11 KAZ 12 Technical Appendix Sat IF Sat IF Sat IF Sat IF...
Страница 124: ...124 Overvoltage protection KAZ 11 KAZ 12 Technical Appendix Sat IF...
Страница 125: ...125 Overvoltage protection KAZ 11 KAZ 12 Technical Appendix Sat IF Sat IF...
Страница 130: ...130 For your Notes...
Страница 131: ...131 For your Notes...