MULTICAL®
603
96
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
2029_A1_GB_06.2017
7.1.3
Outlet
energy
registers
A1
and
A2
The
function
behind
the
“Outlet
energy
registers”
is
that
A1
accumulates
heat
energy
consumed
with
low
outlet
temperature
for
which
the
customer
receives
a
discount,
and
A2
accumulates
heat
energy
consumed
with
high
outlet
temperature
for
which
the
consumer
receives
a
surcharge.
The
energy
calculations
of
a
heat
meter
with
flow
sensor
in
outlet
are
shown
below:
A1
=
m
3
x
(t5
‐
t2)k
t2
Heat
energy
with
discount
A2
=
m
3
x
(t2
‐
t5)k
t2
Heat
energy
with
surcharge
The
outlet
temperature
reference
t5
can
be
factory
‐
configured
as
required,
or
can
be
changed
via
METERTOOL
HCW
after
delivery.
Typical
configuration
is
t5
=
50
°C.
Symbol
Explanation
Measuring
unit
t1
Inlet
temperature
[°C]
t2
Outlet
temperature
t5
Outlet
temperature
reference
E1
Total
heat
energy
[kWh],
[MWh],
[GJ],
[Gcal]
A1
Heat
energy
at
a
discount
A2
Heat
energy
with
an
addition
As
the
accuracy
of
the
absolute
temperature
has
direct
influence
on
the
accuracy
of
outlet
energy
registers
A1
and
A2,
the
zero
error
of
the
sensor
pair
and
the
influence
from
the
sensors’
connection
cable
ought
to
be
compensated
via
the
offset
adjustment
of
MULTICAL®
603
(see
paragraph
7.3).