MULTICAL®
603
74
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
2029_A1_GB_06.2017
6.3
SETUP
loop
In
this
loop,
it
is
possible
to
configure
the
meter
via
the
front
keys.
This
enables
the
technician
to
configure
the
meter
both
before
installation
and
when
the
meter
has
been
put
into
operation.
Configuration
of
the
meter
after
commissioning
requires
that
the
installation
seal
is
broken
and
that
the
meter
top
is
separated
from
the
meter
base.
How
to
open
the
SETUP
loop
1.
In
general
(unless
otherwise
informed
by
the
customer),
the
SETUP
loop
is
available
when
the
meter
is
in
transport
state.
The
meter
leaves
the
transport
state
when
the
meter
for
the
first
time
registers
a
flow
of
1
%
of
qp
or
larger,
or
if
the
SETUP
loop
is
ended
via
the
menu
item
“EndSetup”.
A
total
reset
of
the
meter
is
the
only
way
to
return
to
transport
state.
2.
When
the
meter
is
in
operation,
i.e.
the
meter
has
left
transport
state,
it
is
possible
to
access
the
SETUP
loop
by
breaking
the
meter’s
installation
seal
and
separating
the
meter
top
from
the
meter
base.
How
to
exit
the
SETUP
loop
You
can
exit
the
SETUP
loop
in
three
ways.
All
three
ways
can
be
used
both
in
transport
state
and
after
the
meter
has
been
put
into
operation.
1.
Keep
the
primary
key
activated
and
navigate
to
the
meter’s
other
loops.
2.
After
4
minutes,
the
meter
will
reach
time
‐
out
and
return
to
the
first
reading
in
the
USER
loop.
3.
Navigate
to
the
menu
item
“EndSetup”
in
the
SETUP
loop,
and
keep
the
primary
key
activated
for
5
seconds,
while
the
frames
around
the
reading
increments,
and
the
display
in
the
end
shows
“OK”.
Note:
This
locks
the
access
to
the
SETUP
loop,
and
thereby
the
meter
is
locked
against
further
configuration.
Subsequent
reconfiguration
of
the
meter
requires
that
you
break
the
installation
seal.
As
it
appears
from
the
table
above,
the
purpose
of
the
menu
item
“EndSetup”
is
to
enable
the
technician
to
lock
the
access
to
the
SETUP
loop
in
transport
state
and
thus
lock
the
meter
against
further
configuration.
This
function
is
e.g.
relevant
to
a
technician
who
knows
that
a
meter
is
to
be
mounted
in
the
installation
for
some
time
before
the
first
integration
is
carried
out
and
wants
to
lock
the
access
to
the
SETUP
loop
immediately
after
the
installation
to
ensure
that
no
further
configuration
is
possible.
Please
note
that
it
is
only
possible
to
configure
the
meter
50
times
via
the
SETUP
loop.
After
50
times,
the
meter
is
locked
against
further
configuration,
and
total
reset
and
reverification
of
the
meter
are
required
to
regain
access
to
the
SETUP
loop.
IMPORTANT:
“EndSetup”
is
an
important
function
when
the
meter
is
in
transport
state,
but
when
the
meter
is
in
operation,
“EndSetup”
is
just
one
of
three
ways
to
exit
the
SETUP
loop.