3.2.7
Integration
mode
>L<
MULTICAL®
603
uses
time
‐
based
integration,
which
means
that
accumulated
volume
and
energy
are
calculated
at
fixed,
or
variable,
time
intervals.
The
time
interval
is
configurable
via
the
L
‐
code
and
independent
of
the
water
flow
speed.
Please
be
aware
that
choice
of
integration
mode
in
combination
with
selected
power
supply
defines
the
meter’s
battery
lifetime.
Please
see
paragraph
10.3
re
the
meter’s
battery
lifetime.
It
is
possible
to
choose
between
eight
integration
modes;
five
modes
where
the
meter’s
display
remains
turned
on,
and
three
modes
where
the
meter’s
display
is
turned
off
8
min.
after
the
latest
registered
activation
of
a
key
(4
min.
after
the
latest
registered
activation
of
the
key,
the
meter
returns
to
its
first
primary
reading,
and
after
additional
4
min.,
the
display
turns
off).
In
periods
with
the
display
switched
off,
a
display
segment
flashes
at
an
interval
of
30
s
to
indicate
that
the
meter
is
active
(“heart
beat”
indication).
MULTICAL®
603
can
be
ordered
with
a
backlit
display
(meter
type
603
‐
F).
With
the
exception
of
integration
mode
9,
it
applies
that
the
background
lighting
is
activated
by
pressing
a
key
and
remains
lit
for
15
s.
If
integration
mode
9
is
selected,
the
display
and
the
background
lighting
both
remain
turned
on
(mains
supply
is
required).
L
‐
code
Integration
mode
Backlight
period
(only
603
‐
F)
Display
on
Display
off
Adaptive
mode
(2
‐
64
s)
15
s.
1
5
Normal
mode
(32
s)
15
s.
2
6
Fast
mode
(8
s)
15
s.
3
7
Mains
mode
(2
s)
15
s.
4
‐
Mains
mode
(2
s)
On