MULTICAL®
603
116
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
2029_A1_GB_06.2017
8.1.1.2
Auto
Detect
with
two
ULTRAFLOW®
X4
on
V1
and
V2
The
procedure
for
Auto
Detect
with
two
ULTRAFLOW®
X4
is
identical
to
the
table
in
paragraph
8.1.1.1,
except
for
item
②
where
an
identical
ULTRAFLOW®
X4
connected
to
input
V2
is
mounted.
ULTRAFLOW®
X4,
which
is
mounted
on
V1,
will
always
be
decisive
for
correct
pulse
figure
and
qp,
also
for
an
application
in
which
two
ULTRAFLOW®
X4
are
used.
This
means
that
changing
ULTRAFLOW®
X4
on
V2
will
not
result
in
a
configuration
logging,
but
only
cause
an
information
code.
The
info
code
will
be
present
until
ULTRAFLOW®
X4
on
either
input
V1
or
input
V2
has
been
exchanged
so
that
both
ULTRAFLOW®
X4
are
identical.
Changing
ULTRAFLOW®
X4
to
another
pulse
figure
or
qp
on
input
V1
always
results
in
a
configuration
logging.
Note
that
Auto
Detect
with
two
ULTRAFLOW®
X4
requires
that
the
meter
has
been
configured
for
2
ULTRAFLOW®
(Connection
type
2
or
8)
and
at
the
same
time
that
CCC
=
8xx
has
been
selected.
8.1.1.3
Auto
Detect
information
codes
In
case
of
incorrect
ULTRAFLOW®
or
communication
error
with
ULTRAFLOW®
X4,
MULTICAL®
603
shows
a
static
info
code,
describing
the
occurred
error
(item
⑤
in
the
table
in
paragraph
8.1.1.1).
The
table
below
describes
the
possible
info
codes
and
their
meaning.
Information
code
Description
Remedy
Display duration 5 s
Communication
error
on
input
V1.
Separate
the
calculator,
and
check
that
ULTRAFLOW®
X4
has
been
mounted
correctly
in
the
screw
terminals
of
input
V1.
Then,
repeat
the
procedure
in
paragraph
8.1.1.1
from
item
③
.
Display duration 5 s
Wrong
pulse
figure
on
input
V1.
The
config
log
is
full.
It
is
no
longer
possible
to
exchange
ULTRAFLOW®
X4
on
input
V1
with
a
size
that
differs
from
the
latest
logged
size
of
V1.
Display duration 5 s
Communication
error
on
input
V2.
Separate
the
calculator,
and
check
that
ULTRAFLOW®
X4
has
been
mounted
correctly
in
the
screw
terminals
of
input
V2.
Then,
repeat
the
procedure
in
paragraph
8.1.1.1
from
item
③
.
Display duration 5 s
Wrong
pulse
figure
on
input
V2.
ULTRAFLOW®
X4
on
input
V2
differs
from
ULTRAFLOW®
X4
on
input
V1.
Make
sure
that
both
ULTRAFLOW®
X4
are
identical,
and
repeat
the
procedure
in
paragraph
8.1.1.1.
Display duration 5 s
Communication
error
on
both
input
V1
and
input
V2.
Separate
the
calculator,
and
check
that
ULTRAFLOW®
X4
has
been
mounted
correctly
in
the
screw
terminals
of
input
V1
and
of
input
V2.
Then,
repeat
the
procedure
in
paragraph
8.1.1.1
from
item
③
.
In
applications
with
two
ULTRAFLOW®
X4,
both
ULTRAFLOW®
X4
must
be
exchanged
to
the
same
type,
i.e.
identical
pulse
figures
and
qp.
If
pulse
figure
and
qp
are
not
identical,
this
results
in
an
info
code,
see
the
description
in
paragraph
8.1.1.4.