Time
‐
controlled
tariff
The
time
‐
controlled
tariff
is
used
for
time
division
of
heat
consumption.
If
TL2
=
08:00,
TL3
=
16:00
and
TL4=23:00,
the
daily
consumption
from
08:00
until
15:59
is
accumulated
in
TA2,
whereas
the
consumption
during
the
evening
from
16:00
until
22:59
is
accumulated
in
TA3,
and
the
consumption
during
the
night
from
23:00
until
07:59
is
accumulated
in
TA4.
TL2
must
include
fewer
hours
than
TL3
and
TL3
must
include
fewer
hours
than
TL4.
From
and
incl.
TL2
to
TL3
Accumulation
in
TA2
and
main
register
TL3
must
follow
TL2
TL4
must
follow
TL3
From
and
incl.
TL3
to
TL4
Accumulation
in
TA3
and
main
register
From
and
incl.
TL4
to
TL2
Accumulation
in
TA4
and
main
register
The
time
‐
controlled
tariff
is
suitable
for
billing
in
housing
areas
close
to
industrial
areas
with
large
district
heating
consumption
as
well
as
for
billing
industrial
customers.
EE=20
Heat/cooling
volume
tariff
The
heat/cooling
volume
tariff
is
used
to
divide
volume
into
heat
and
cooling
consumption
in
combined
heat/cooling
meters,
i.e.
the
tariff
divides
the
consumed
volume
into
heat
and
cooling
volume
for
combined
heat/cooling
meters.
The
total
volume
is
accumulated
in
the
register
V1,
whereas
TA2
accumulates
the
volume
consumed
together
with
E1
(heat
energy),
and
TA3
accumulates
the
volume
consumed
together
with
E3
(cooling
energy).
EE=20
only
functions
in
heat/cooling
meters
of
the
meter
types
3
and
6.
(TA4
is
not
used
in
this
tariff
type).
t1
t2
and
t1
hc
Volume
is
accumulated
in
TA2
and
V1
(heat
energy)
TL2
and
TL3
are
not
used
t1
t2
and
t1
≤
hc
Volume
is
accumulated
in
V1
only
t2
t1
and
t1
≤
hc
Volume
is
accumulated
in
TA3
and
V1
(cooling
energy)
t2
t1
and
t1
hc
Volume
is
accumulated
in
V1
only
t1
=
t2
and
t1
hc
Volume
is
accumulated
in
V1
only,
no
counting
in
energy
registers
t1
=
t2
and
t1
≤
hc
Volume
is
accumulated
in
V1
only,
no
counting
in
energy
registers
EE=21
PQ
tariff
The
PQ
tariff
is
a
combined
power
and
flow
tariff.
TA2
functions
as
power
tariff,
and
TA3
functions
as
flow
tariff.
P
TL2
and
Q
TL3
Accumulation
in
main
register
only
TL2
=
power
limit
(P)
TL3
=
flow
limit
(Q)
P
TL2
Accumulation
in
TA2
and
main
register
Q
TL3
Accumulation
in
TA3
and
main
register
P
TL2
and
Q
TL3
Accumulation
in
TA2,
TA3
and
main
register
The
PQ
tariff
can
e.g.
be
used
for
customers
who
pay
a
fixed
charge
based
on
max
power
and
max
flow
(TL4
and
TA4
are
not
used
in
this
tariff
type).