MULTICAL®
603
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
2029_A1_GB_06.2017
85
7
Calculator
functions
7.1
Application
types
and
energy
calculations
MULTICAL
603
operates
with
15
different
energy
formulas,
E1,
E2,
E3,
E4,
E5,
E6,
E7,
E8,
E9,
E10,
E11,
A1,
A2,
dE
and
cE,
which
are
all
calculated
parallel
with
each
integration,
irrespective
of
how
the
meter
is
configured.
E8
and
E9
are
used
as
a
basis
of
the
calculation
of
average
temperatures
of
inlet
and
outlet,
whereas
E1
and
E3
are
used
for
heat
and
cooling
measurement,
respectively.
E4
to
E7
are
used
in
a
number
of
energy
applications
that
are
shown
below.
A1
and
A2
are
used
as
a
basis
for
discount/surcharge
based
on
the
outlet
temperature
(see
paragraph
7.1.3).
Formula
Example
of
application
Included in
application
no.
Register
type
E1=V1(t1
‐
t2)k
t1:
Inlet
/
t2:
Outlet
t1
>
t2
Heat
energy
(V1
in
inlet
or
outlet)
1+2+3+4+5+6+8+10
Legal
Display/Data/Log
E2=V2(t1
‐
t2)k
t2:
Outlet
t1
>
t2
Heat
energy
(V2
in
return)
2+7
Display/Data/Log
E3=V1(t2
‐
t1)k
t2:
Inlet
/
t1:
Outlet
t2
>
t1
Cooling
energy
(V1
in
inlet
or
outlet) 1+11
Legal
Display/Data/Log
E4=V1(t1
‐
t3)k
t1:
Inlet
t1
>
t3
Forward
energy:
7+9+11
Display/Data/Log
E5=V2(t2
‐
t3)k
t2:
Inlet
t2
>
t3
Outlet
energy
or
tap
from
outlet
5+7+9
Display/Data/Log
E6=V2(t3
‐
t4)k
t3:
Inlet
t3
>
t4
Tap
water
energy,
separate
3+6
Display/Data/Log
E7=V2(t1
‐
t3)k
t3:
Outlet
t1
>
t3
Return
energy
or
tap from
flow
4+8
Display/Data/Log
E8=V1(m
3
)
x
t1
‐
Average
temperature
in
inlet
See
paragraph
7.1.2.
Display/Data/Log
E9=V1(m
3
)
x
t2
‐
Average
temperature
in
outlet
Display/Data/Log
E10=V1(m
3
)
x
t3
‐
Average
t3
in
V1
Display/Data/Log
E11=V2(m
3
)
x
t3
‐
Average
t3
in
V2
Display/Data/Log
A1
t5
>
t2
Heat
energy
at
a
discount
See
paragraph
7.1.3.
Display/Data/Log
A2
t2
>
t5
Heat
energy
with
an
addition
Display/Data/Log
dE=E4
‐
E5
‐
Differential
energy
7
‐
cE=E5
‐
E4
‐
Control
of
differential
energy
7
‐
Symbols
used
in
application
figures
Temperature
sensor
Stop
valve
Flow
sensor
Calculator
Consumer,
e.g.
radiators
Non
‐
return
valve
Heat
exchanger
Содержание MULTICAL 603
Страница 1: ...Technical description MULTICAL 603...