MULTICAL®
603
48
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
2029_A1_GB_06.2017
The
table
below
is
a
part
of
the
type
number
overview,
which
shows
the
module
type
numbers.
The
table
distinguishes
between
modules
with
pulse
inputs
(In
‐
A,
In
‐
B)
and
modules
with
pulse
outputs
(Out
‐
C,
Out
‐
D).
Modules
Data
+
2
pulse
inputs
(In
‐
A,
In
‐
B)
10
Data
+
2
pulse
outputs
(Out
‐
C,
Out
‐
D)
11
M
‐
Bus,
configurable
+
2
pulse
inputs
(In
‐
A,
In
‐
B)
20
M
‐
Bus,
configurable
+
2
pulse
outputs
(Out
‐
C,
Out
‐
D)
21
M
‐
Bus,
configurable
+
Thermal
Disconnect
22
Wireless
M
‐
Bus,
configurable,
868
MHz
+
2
pulse
inputs
(In
‐
A,
In
‐
B)
1
30
Wireless
M
‐
Bus,
configurable,
868
MHz
+
2
pulse
outputs
(Out
‐
C,
Out
‐
D)
1
31
Analog
output
module
2
x
0/4…20
mA
40
Analog
input
module
2
x
0/4…20
mA
41
LON
FT
‐
X3
+
2
pulse
inputs
(In
‐
A,
In
‐
B)
60
BACnet
MS/TP
+
2
pulse
inputs
(In
‐
A,
In
‐
B)
66
Modbus
RTU
+
2
pulse
inputs
(In
‐
A,
In
‐
B)
67
1
Internal or external antenna
Below
please
find
specification
of
requirements
to
pulse
duration
and
pulse
frequency
for
meters
connected
to
pulse
inputs:
Pulse
outputs
C
and
D
Out
‐
C:
16
‐
17
and
Out
‐
D:
18
‐
19
via
module
Pulse
duration:
Pulse
value
When pulse outputs are used for
e.g. remote counting of energy and
volume with the same resolution as
the display
1
Heat
meter:
Out
‐
C
=
CE+
Out
‐
D
=
CV
Cooling
meter:
Out
‐
C
=
CE
‐
Out
‐
D
=
CV
Heat/cooling
meter:
Out
‐
C
=
CE+
Out
‐
D
=
CE
‐
Selectable:
10
ms,
32
ms
or
100
ms
Pulse
value
When pulse outputs are used as
pulse transmitter/divider for e.g.
regulation purposes
Transmitter:
Out
‐
C
=
V1
Out
‐
D
=
V2
4
ms
Divider:
Out
‐
C
=
V1/4
22
ms
Communication
module
Type
HC
‐
003
‐
21
Type
HC
‐
003
‐
11
Type
HC
‐
003
‐
11
Before
2017
‐
05
‐
01
After
2017
‐
05
‐
01
Pulse
output
type
Open
collector
(OB)
Open
collector
(OB)
Opto
FET
External
voltage
5…30
VDC
5…30
VDC
5…48
VDC/AC
Current
1…10
mA
1…10
mA
1…50
mA
Residual
stress
U
CE
≈
1
V
at
10
mA
U
CE
≈
1
V
at
10
mA
R
ON
≤
40
Electrical
isolation
2
kV
2
kV
2
kV
Max
cable
length
25
m
25
m
25
m
1
At high resolution, the pulse outputs will be reduced by 1:10 when selecting 32 ms and 100 ms. See paragraph 3.2.10
about PP codes.