50
The error messages that may appear on the display are listed in the table in figure 50:
TROUBLESHOOTING, FAULTS AND MAINTENANCE
ERROR MESSAGES
ER.No
MESSAGE
CAUSE
REMEDY
01
SIMMER ERROR
The Laser lamp does not switch on
A. Check the fuse
B. Call CUSTOMER SERVICE
02
COOLANT AT
STILLSTAND
The coolant is at stillstand inside
the cooling pipes
A. Pump stopped
B.
Water dirty or cloudy
A. Check the fuse and call
CUSTOMER SERVICE
B. Check the colour of the coolant
through the openings and if
there is any sediment on the
bottom of the tank. If so,
replace the coolant and
clean the cooling system.
03
COOLANT
TEMPERATURE HIGH
The coolant has reached the
warning temperature (55 °C):
A. Intensive machine working
cycle
B.
Insufficient coolant in the
storage tank
C.
Lateral cooling fan not running
D.
Excess dust or dirt deposited
on the heat pump
A. Wait 15 minutes, without
switching the machine off, for
the error to disappear; if it does
not, call CUSTOMER SERVICE
B. Check the coolant level in the
tank, viewing it from the side,
and top-up with distilled water
if necessary
C. Check the operation of the fan,
which, in the case of Error 01,
should run very fast, generating
considerable noise. If not, call
CUSTOMER SERVICE
D. Direct a jet of compressed air
through the openings in order
to free the heat pump of any
dust. Do not open the machine
before first having consulted
the CUSTOMER SERVICE
04
ELECTRONIC POWER
UNIT TEMPERATURE
HIGH
The thermostat located inside the
electronic power unit has detected
a high temperature:
A.
Intensive machine working cycle
B.
Dirt or dust deposited on the
rear cooling fans
C.
Rear cooling fans not running
A. Wait a few minutes for the error
to disappear and leave the
machine to cool down for
around 20 minutes
B.
Direct a jet of compressed air
through the openings on the
rear panel to determine whether
there is any dirt or dust
deposited on the fans. Before
opening the machine, call
CUSTOMER SERVICE
C.
Call CUSTOMER SERVICE
05
INPUT RELAY
The machine is switched on but
cannot be used for welding
A. Problems with the power supply
A. Check the power supply
connections
B. Replace the power supply
06
CAPACITOR
VOLTAGE LOW
The electronic power unit has failed
to charge the capacitor bank
A. The generator is faulty
A. Call CUSTOMER SERVICE
Figure 50 – Error table
Содержание 4910880
Страница 1: ......
Страница 4: ......
Страница 6: ...SAFETY ...
Страница 18: ...INTRODUCTION ...
Страница 24: ...INSTALLATION ...
Страница 40: ...SETTING THE MACHINE PARAMETERS ...
Страница 44: ...WELDING WITH THE ENESKAlaser 1500 mobile ...
Страница 48: ...TROUBLESHOOTING FAULT MAINTENANCE ...
Страница 60: ...GENERAL SAFETY REQUIREMENTS DURING WELDING ...
Страница 65: ...NOTE ...
Страница 66: ...NOTE ...
Страница 67: ...NOTE ...