31
JOYSTICK
• Moving the joystick to the LEFT or RIGHT will cause the arm to move along the X AXIS;
• Moving the joystick FORWARD or BACK will cause the arm to move along the Y AXIS;
• Rotating the joystick CLOCKWISE or COUNTER-CLOCKWISE will cause the arm to move along the Z
AXIS;
INSTALLATION
POSITIONS OF CONTROLS
Figure 25 – Joystick controls
Figure 26 – Joystick button options
Reference
Description
A
Emergency stop mushroom push-button
B
Ignition key
C
Mobile shielding gas diffusor
Figure 24 – Controls
X+
X-
Y+
Y-
Z-
Z+
• By pressing the buttons on the joystick it is possible to
use 3 different confi gurations, which may be selected
via the touch screen display by pressing the icon, at
the bottom left of the display highlighted in fi gure 26:
1. Maintain button P1 and P2 pressed to change the
spindle rotation direction from CLOCKWISE to
COUNTER-CLOCKWISE, or vice versa, when it is
present and connected.
2. Maintain button P1 and P2 pressed while the
axes are moving to change the travel speed from
MINIMUM to MAXIMUM or vice versa;
3. Press BUTTONS P1 and P2 simultaneously to
activate laser beam emission;