Table 95: R-134a pressure to saturated temperature conversion
Pressure
psig (bar)
Dew point
temperature
ºF (ºC)
Pressure
psig (bar)
Dew point
temperature
ºF (ºC)
Pressure
psig (bar)
Dew point
temperature
ºF (ºC)
0.0 (0.0)
-14.9 (-26.1)
135.0 (9.31)
105.0 (40.6)
270.0 (18.62)
152.0 (66.7)
5.0 (0.34)
-3.0 (-19.4)
140.0 (9.65)
107.2 (41.8)
275.0 (18.96)
153.4 (67.4)
10.0 (0.69)
6.7 (-14.1)
145.0 (10.0)
109.4 (43.0)
280.0 (19.31)
154.7 (68.2)
15.0 (1.03)
14.9 (-9.5)
150.0 (10.34)
111.5 (44.2)
285.0 (19.65)
156.1 (68.9)
20.0 (1.38)
22.2 (-5.4)
155.0 (10.69)
113.6 (45.3)
290.0 (19.99)
157.4 (69.7)
25.0 (1.72)
28.7 (-1.8)
160.0 (11.03)
115.6 (46.4)
295.0 (20.34)
158.7 (70.4)
30.0 (2.07)
34.6 (1.4)
165.0 (11.38)
117.6 (47.6)
300.0 (20.68)
160.0 (71.1)
35.0 (2.41)
40.0 (4.4 )
170.0 (11.72)
119.6 (48.7)
305.0 (21.03)
161.3 (71.8)
40.0 (2.76)
45.0 (7.2)
175.0 (12.07)
121.5 (49.7)
310.0 (21.37)
162.5 (72.5)
45.0 (3.10)
49.6 (9.8)
180.0 (12.41)
123.3 (50.7)
315.0 (21.72)
163.8 (73.2)
50.0 (3.45)
54.0 ( 12.2)
185.0 (12.76)
125.2 (51.8)
320.0 (22.06)
165.0 (73.9)
55.0 (3.79)
58.1 (14.5)
190.0 (13.10)
126.9 (52.7)
325.0 (22.41)
166.2 (74.6)
60.0 (4.14)
62.0 (16.7)
195.0 (13.44)
128.7 (53.7)
330.0 (22.75)
167.4 (75.2)
65.0 (4.48)
65.7 (18.7)
200.0 (13.79)
130.4 (54.7)
335.0 (23.10)
168.6 (75.9)
70.0 (4.83)
69.2 (20.7)
205.0 (14.13)
132.1 (55.6)
340.0 (23.44)
169.8 (76.6)
75.0 (5.17)
72.6 (22.6)
210.0 (14.48)
133.8 (56.6)
345.0 (23.79)
171.0 (77.2)
80.0 (5.52)
75.9 (24.4)
215.0 (14.82)
135.5 (57.5)
350.0 (24.13)
172.1 (77.8)
85.0 (5.86)
79.0 (26.1)
220.0 (15.17)
137.1 (58.4)
355.0 (24.48)
173.3 (78.5)
90.0 (6.21)
82.0 (27.8)
225.0 (15.51)
138.7 (59.3)
360.0 (24.82)
174.4 (79.1)
95.0 (6.55)
84.9 (29.4)
230.0 (15.86)
140.2 (60.1)
365.0 (25.17)
175.5 (79.7)
100.0 (6.89)
87.7 (30.9)
235.0 (16.20)
141.8 (61.0)
370.0 (25.51)
176.6 (80.3)
105.0 (7.24)
90.4 (32.4)
240.0 (16.55)
143.3 (61.8)
375.0 (25.86)
177.7 (80.9)
110.0 (7.58)
93.0 (33.9)
245.0 (16.89)
144.8 (62.3)
380.0 (26.20)
178.8 (81.6)
115.0 (7.93)
95.5 (35.3)
250.0 (17.24)
146.3 (63.5)
385.0 (26.54)
179.9 (82.2)
120.0 (8.27)
98.0 (36.7)
255.0 (17.58)
147.7 (64.3)
390.0 (26.89)
180.9 (82.7)
125.0 (8.62)
100.4 (38.0)
260.0 (17.93)
149.2 (65.1)
395.0 (27.23)
182.0 (83.3)
130.0 (8.96)
102.7 (39.3)
265.0 (18.27)
150.6 (65.9)
400.0 (27.58)
183.0 (83.9)
Before charging, establish that starting weight for the refrigerant cylinder. When the chiller has
been vapor charged to the appropriate saturation pressure, you might need to use a refrigerant
pump to draw vapor from the chiller and discharge it to the vapor connection of the refrigerant
cylinder. This helps to create a pressure differential for pushing the refrigerant liquid from the
cylinder to the chiller.
While charging, take every precaution to prevent air from entering the system. Create a suitable
charging connection from new copper tubing or correctly selected flexible charging hoses. Fit this
charging connection between the system charging valve and the fitting on the charging drum.
This connection must be as short as possible but long enough to provide sufficient flexibility for
changing drums. It must also contain a tee fitting with a valve that can serve as a connection point
to a vacuum pump to evacuate the charging lines.
The charging connection must be evacuated each time the lines are disconnected for changing
cylinders or any of the components of the charging process.
The charging line must also contain a sight glass. When liquid charging is performed, the sight
glass can be monitored to determine when the liquid is no longer being transferred to the chiller.
The refrigerant charge is specified for each chiller model on the unit data plate or in the factory
order form (FOF) that is provided for every new sale. Charge the chiller based on the amount
specified in the FOF less 10%. For example, for a chiller that requires 500# of refrigerant, the
initial refrigerant charge is 450#, 500 - 50 = 450. This allows room to trim the charge as outlined in
Checking and trimming the refrigerant charge
133
YVAM Control Center
Содержание YORK YVAM 0350
Страница 2: ...2 YVAM Control Center...
Страница 10: ...Figure 4 Variable speed drive nomenclature YVAM Control Center 10...
Страница 15: ...Figure 8 System piping and instrumentation diagram P ID 15 YVAM Control Center...
Страница 118: ...Figure 47 Drive logic board Callout Component Callout Component A U35 B U38 C U37 D U36 YVAM Control Center 118...
Страница 154: ...Figure 62 Sample printout status or history YVAM Control Center 154...
Страница 155: ...Figure 63 Sample printout status or history continued 155 YVAM Control Center...
Страница 156: ...Figure 64 Sample printout setpoints YVAM Control Center 156...
Страница 157: ...Figure 65 Sample printout setpoints continued 157 YVAM Control Center...
Страница 158: ...Figure 66 Sample printout schedule YVAM Control Center 158...
Страница 159: ...Figure 67 Sample printout sales order 159 YVAM Control Center...
Страница 160: ...Figure 68 Sample printout security log report YVAM Control Center 160...