SECTION 5 - JLG CONTROL SYSTEM
5-54
31215923
7773
7
7 "Rear Left Motor - Open Circuit"
Drive, Lift Up and Leveling Jack Func-
tions are Prevented.
• UGM is detecting that the Left Power Module is communi-
cating that the Left Drive Motor Phase Voltage value is read-
ing as an open circuit.
• Check the Drive Motor Phase Voltage cable connections W, U
and V are properly connected at the drive motor. Check the
cable connections at the module terminals. Check the cables
for continuity or damage.
7774
7
7 "Rear Right Motor - Open Circuit"
Drive, Lift Up and Leveling Jack Func-
tions are Prevented.
• UGM is detecting that the Right Power Module is communi-
cating that the Right Drive Motor Phase Voltage value is
reading as an open circuit.
• Check the Drive Motor Phase Voltage cable connections W, U
and V are properly connected at the drive motor. Check the
cable connections at the module terminals. Check the cables
for continuity or damage.
8113
8
1 “Front Axle Tilt Sensor Has Not Calibrated” Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
• The UGM is detecting that the Front Axle Tilt Sensor does not
have a Calibrated Value in Memory.
8114
8
1 “Arm Stack Tilt Sensor Out Of Range”
Lift Up is Prevented.
• The UGM is detecting that the Arm Stack Tilt Sensor Value is
reading greater than 80° or less than -15°.
• Check sensor for damage or faulty wiring.
8115
8
1 “Front Axle Tilt Sensor Out Of Range”
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
Axle Tilt Calibration Prevented.
• The UGM is detecting that the Front Axle Tilt Sensor Value is
reading greater than +/- 30°
• Check sensor for damage or faulty wiring.
8118
8
1 “Front Axle Tilt Sensor Stagnant”
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
Axle Tilt Calibration Prevented.
• The UGM is detecting that the Front Axle Tilt Sensor Value is
not changing during Drive.
• Check sensor for damage or faulty wiring.
8120
8
1 “Arm Stack Tilt Sensor - Disagreement"
Lift Up is Prevented.
• The Arm Stack Tilt Sensor has an internal accelerometer dis-
agreement. Tilt Sensor will need replaced.
8121
8
1 “Front Axle Tilt Sensor - Disagreement”
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
• The Front Axle Tilt Sensor has an internal accelerometer dis-
agreement. Tilt Sensor will need replaced.
813
8
1 “Chassis Tilt Sensor Not Calibrated”
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
• The UGM is detecting that the Chassis Tilt Sensor does not
have a Calibrated Value in Memory.
814
8
1 “Chassis Tilt Sensor Out Of Range”
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
• The UGM is detecting that the Chassis Tilt Sensor Value is
reading greater than +/- 30°.
• Check sensor for damage or faulty wiring.
815
8
1 “Chassis Tilt Sensor - Disagreement”
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
• The Chassis Tilt Sensor has an internal accelerometer dis-
agreement. Tilt Sensor will need replaced.
818
8
1 “Tilt Sensor Stagnant”
Lift Up is Prevented. Drive is pre-
vented if the Machine is Not Stowed.
• The UGM is detecting that the Chassis Tilt Sensor Value is not
changing during Drive.
• Check sensor for damage or faulty wiring.
821
8
2 “LSS Front Left Cell #1 Error”
Machine will behave as if it is over-
loaded.
• UGM is detecting that LSS FL Cell has an Error.
• Check for cable damage or loose connection.
822
8
2 “LSS Front Right Cell #2 Error”
Machine will behave as if it is over-
loaded.
• UGM is detecting that LSS FR Cell has an Error.
• Check for cable damage or loose connection.
823
8
2 “LSS Rear Left Cell #3 Error”
Machine will behave as if it is over-
loaded.
• UGM is detecting that LSS RL Cell has an Error.
• Check for cable damage or loose connection.
824
8
2 “LSS Rear Right Cell #4 Error”
Machine will behave as if it is over-
loaded.
• UGM is detecting that LSS RR Cell has an Error.
• Check for cable damage or loose connection.
825
8
2 “LSS Has Not Been Calibrated”
Machine will behave as if it is over-
loaded.
• UGM is detecting that the LSS does not have a Calibrated
Value in Memory.
DTC
Code
Flash
Code
Description
Action
Item Check List
Содержание ERT2669
Страница 2: ......
Страница 4: ...INTRODUCTION A 2 31215923 REVISON LOG Original Issue A January 08 2021...
Страница 12: ...viii 31215923 TABLE OF CONTENTS...
Страница 40: ...SECTION 1 SPECIFICATIONS 1 22 31215923...
Страница 58: ...SECTION 2 GENERAL 2 18 31215923...
Страница 187: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 31215923 4 11...
Страница 206: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 4 30 31215923...
Страница 221: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 31215923 4 45 Figure 4 33 Lift Cylinder MAF46290...
Страница 223: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 31215923 4 47 Figure 4 35 Leveling Jack Cylinder MAF46280...
Страница 225: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 31215923 4 49...
Страница 242: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 4 66 31215923...
Страница 307: ...SECTION 5 JLG CONTROL SYSTEM 31215923 5 65...
Страница 334: ...SECTION 6 LSS SETUP CALIBRATION SERVICE 6 12 31215923...
Страница 362: ...SECTION 7 GENERAL ELECTRICAL INFORMATION SCHEMATICS 7 28 31215923...
Страница 374: ...SECTION 7 GENERAL ELECTRICAL INFORMATION SCHEMATICS 7 40 31215923...
Страница 375: ......