Jetter AG
Electrical connection | 6
User Manual – JetControl 365MC
29 / 148
6.2 Ports and interfaces
6.2.1 Selector switch S11 - Mode selector
During boot-up, the controller acquires the position of the mode selector.
Depending on the switch position, the controller behaves differently after the boot
phase. Any changes made to the mode selector while the controller is running will
have no effect on the operating mode.
Switch position
RUN
STOP
LOAD
Operating mode
Description
RUN
The controller launches the application program.
STOP
The controller does not launch the application
program.
LOAD
The controller does not launch the application
program.
The controller executes the AutoCopy function.
Once the AutoCopy function is completed, the
controller must be restarted.
Tab. 18:
Switch positions of mode selector S11
Functions of the mode selector
In checking the position of mode selector S11 the JC-365MC proceeds in the fol-
lowing way:
Step
Description
1
Power supply of the controller is at terminal X10.
2
The boot loader of the controller checks the position of selector S11.
If ...
... then ...
... mode selector S11 =
RUN
or
STOP
,
... the OS is launched;
--> proceed with step 4
... selector S11 =
LOAD
position,
and an SD card has been inserted,
... the OS is launched;
--> proceed with step 3
... selector S11 =
LOAD
position,
and an SD card has not been in-
serted,
... the boot loader waits until an OS
update is carried out.
3
The controller loads the
autocopy.ini
file.
If ...
... then ...
... the file could be loaded,
... the instructions contained in it
are executed.
... the file could not be loaded,
... the instructions cannot be exe-
cuted.
4
The controller checks the position of selector S11.
If ...
... then ...
... mode selector S11 =
RUN
,
... the application program is
launched.
... mode selector S11 =
STOP
,
... the application program does not
start.