![Jetter JetControl 365MC Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/jetter/jetcontrol-365mc/jetcontrol-365mc_user-manual_3889149124.webp)
Jetter AG
Registers - Overview | 9
HMI control
Registers
Description
222804
Total number of display characters
222805
Number of characters per line
222806
Text selection (DisplayText2)
222808
Number of decimal places (UserIn-
put)
222810
Number of decimal places (Dis-
playValue)
222811
Max. number of decimal places
(UserInput)
222812
Field length (DisplayValue)
222813
Field length (UserInput)
222814
Indirect cursor position
222815
Default value for UserInput (Inte-
ger/Float)
222816
Displaying the sign
222817
Status UserInput
222818
Enable/disable monitor functions
222819
Display text - monitor function
222820
Switching over to monitor display
222821
Dialog language
222824
Indirect buffer number
Multi-display mode
222825
Text buffer for display 1
222826
Text buffer for display 2
222827
Text buffer for display 3
222828
Text buffer for display 4
222829
Basic flag number for display 1
222830
Basic flag number for display 2
222831
Basic flag number for display 3
222832
Basic flag number for display 4
222833
Register number - LED display 1
222834
Register number - LED display 2
222835
Register number - LED display 3
222836
Register number - LED display 4
222837
Module number of PRN (display
redirection)
222838
Module number of SER (display
redirection)
222839
Character code for
Delete display
222840
Character code for
Delete to end
of line
Networking via JetIP
Registers
Description
TCP Autoclose for
JetIP
/TCP server
230000
Number of open connections
230001
Mode
230002
Time
Other registers for networking via
JetIP
232708
Timeout in milliseconds
232709
Response time in milliseconds
232710
Amount of network errors
232711
Error code of last access
0
No error
1
Timeout
3
Error message from remote station
5
Illegal network address
6
Invalid amount of registers
7
Illegal interface number
232717
Maximum number of retries
232718
Number of retries
Network registers
235000 ...
235399
IP addresses
235400 ...
235799
Port numbers
236000 ...
236399
Indirect register numbers
GNN: nnn = 000 ... 199
1nnn020000
...
1nnn179999
JX3 module register
1nnn202000
...
1nnn227999
JX2 module register
1nnn810000
...
1nnn819999
JetMove registers
1nnn980000
...
1nnn980199
Indirect access via local register
236xxx
1nnn990000
...
1nnn999999
Indirect access with variable desti-
nation window
User Manual – JetControl 365MC
124 / 148