P/N 960-100929R_Rev. 7 {EDP #148849}
© 2017, JAPAN CASH MACHINE CO., LTD.
6 - 1 8
Section 6
iVIZION® SeriesNext-Generation Banknote Acceptor Unit
Calibration and Testing
2. Confirm that the “
ICB Function
” Screen shown
in Figure 6-68 appears. Seven (7) Screen Buttons
exist on this Screen.
Enabling the ICB Function
To set the ICB “
Enable
” Function when an RFID
Circuit Board, is installed in the iVIZION Unit.
To set ICB Enable proceed as follows:
1. First, confirm that the Cash Box setting is set to
“
System Enable
b
).
2. Then click on the “
Enable
a
) to activate the ICB Function.
3. When the ICB Function is correctly enabled, the
“
ICB Successfully Enabled.
” pop-up Dialog
Message Window shown in Figure 6-69 will
appear.
4. Click
the
“
OK
” Screen Button (Figure 6-69
a
) to
accept the reported message.
Disabling the ICB Function
The ICB “
Disable
” Function is used when an RFID
Circuit Board IS NOT installed or the ICB Function
is not being used.
To set ICB Disable proceed as follows:
1. Then click on the “
Disable
” Screen
Button (Figure 6-68
b
) to disable the ICB Func-
tion.
2. When the ICB Function is correctly disabled, the
“
ICB Successfully Disabled
” pop-up Dialog
Message Window shown in Figure 6-70 will
appear.
3. Click the “
OK
” Screen Button (Figure 6-70
a
to
accept the reported message).
ICB Current Status Screen Button
To check the current ICB Enable/Disable Setting
Status proceed as follows:
1. Click on the “
ICB Current Status
” Screen But-
a
).
2. The Current ICB Enable/Disable Status will
appear in a Field Window next to the “
ICB Cur-
rent Status
” Screen Button (Figure 6-71
b
).
Figure 6-68
Figure 6-68
ICB Function Screen
a
b
NOTE: If the Cash Box is set to “System
Inhibit” or if the RFID Circuit Board IS NOT
installed, the Status LED will flash at a
Blue
Color rate to notify that an error exists (See
Table 6-7 on page 6-20 of this Section to
resolve this issue).
NOTE: To set the Cash Box setting
“Enable” from “System Inhibit”, the Read-
Write Tool is required.
NOTE: Confirm “System Enable”
condition by “Get ICB System
Status” function (Figure 6-77
a
).
NOTE: When ICB is Enabled, a
Machine Code Number can be
assigned. See “Setting the Machine
Code Number (M/C #)” on page 6-19
Figure 6-69
Figure 6-69
Enable Setting Completion
a
NOTE: If the ICB Function is “Enable”
when the RFID Circuit Board IS NOT
installed, the Status LED will flash at a
Blue
Color rate to notify that an error exists (See
Table 6-7 on page 6-20 of this Section to
resolve this issue).
NOTE: If the RFID Circuit Board IS
installed, set the Cash Box to “System
Inhibit” (See Figure 6-75 on page 6-19).
Figure 6-70
Disable Setting Completion
a
Figure 6-71
ICB Current Status Screen
b
b
a
a