P/N 960-100929R_Rev. 7 {EDP #148849}
© 2017, JAPAN CASH MACHINE CO., LTD.
6 - 1 6
Section 6
iVIZION® SeriesNext-Generation Banknote Acceptor Unit
Calibration and Testing
Performance Test Tool Requirement using an
External DIP Switch Box
Figure 6-62 illustrates and list identifies the Tools
and equipment interconnects necessary to perform
the
iVIZION
Performance Tests using an External
Switch Box.
External DIP Switch Performance Test
Procedure Settings
Table 6-2 lists the DIP Switch settings for the
Performance Tests using the External Switch Box.
Performance Tests with External Switch
Procedures
Perform the following steps to test the Motor
Normal Forward and Reverse Rotation, the Stacker
Motor, the Cyclic Movement Test, the Status LED
Indication Test, the Banknote Transportation and
the ICB Function Setting Performance Tests.
1. Turn the iVIZION Power Switch
OFF
.
2. Remove the Transport Unit from the Frame.
3. Set the appropriate DIP Switch(es) to “
ON
” for
the test desired using the 8-Position DIP Switch
(Table 6-6).
4. Place the Transport Unit back onto the Frame.
5. Connect the third the fourth Pin Connector of the
External Switch Box Cable to the corresponding
Connector Pins of the five (5) Pin Plug located at
the rear side of the iVIZION Transport Unit
6. Set the External Switch Box Switch to the posi-
tion away from the Status LED on the Box.
7. Turn the iVIZION Power Switch to
ON
. The
iVIZION Status LEDs will indicate Stand-by
Mode when the Status LED on the iVIZION
Lights a steady
Blue
Color, and the Status LED
on the External Switch blinks at a
Red
Color rate.
8. Turn the External Switch Box Switch toward the
iVIZION status LED on the Box. The desired
Test selected by DIP Switch Positions will then
begin (Refer to Table 6-6 “Performance Test DIP
Switch Settings” on page 6-16 of this Section for
each test and its resulting Test indication).
9. Return the External Switch Box Switch to the
position away from the iVIZION Status LED on
the Box again, and the current Test being run will
end. If other Switch Box Tests are necessary,
restart from Step 1 at the beginning of this
procedure.
iVIZION Utility Tools
This portion provides information regarding each
iVIZION
Service Mode setting procedure.
The following two (2) Tool setting types exist when
using the iVIZION Utility Tools:
•
CIS Image Views
•
ICB Function Settings.
:
ICB/Image Setting Tool Requirements
Table 6-6
Performance Test DIP Switch Settings
*
*. NOTE: The Sensor ON/OFF Test and the DIP Switch ON/OFF Test
are ONLY available when using the PC procedure!
No. Test Item
Status LED
DIP Switch Setting (O = ON)
Stand-
by
Operat-
ing
1
2
3
4
5
6
7
8
1
Motor
Normal
Rotation
Blue
Lit
Yellow
Flashes
-
O
-
-
-
-
-
O
2
Motor
Reverse
Rotation
O
O
-
-
-
-
-
O
3
Stacker
Motor
-
-
O
-
-
-
-
O
4
Cyclic
Movement
-
-
-
O
-
-
-
O
5
Status LED
Indication
Red
-
-
-
-
O
-
-
O
Green
Blue
6
Banknote
Accept-
ance
Exting-
uished
(Out)
O
O
O
O
-
-
-
O
7
ICB Setting
(Reading
Ticket)
O
-
-
O
-
-
-
O
Figure 6-62
Calibration Tool Requirements
a) iVIZION Unit
b) Power Supply (12V DC - 24V DC)
c) External Switch Box
(User provided)
d) Interface Cable (3380-05-01 EDP#146780)
a
b
c
MOLEX 4-Pin
MOLEX 3-Pin
MOLEX 2-Pin
NOTE: Refer to Figure 6-1 and Figure 6-2
for the necessary Tools and Harness
Connections and USB Cable Type
Requirements respectively.
NOTE: The ICB Function Status is initially
Factory Set to “INHIBIT” as a standard
function. Therefore, the iVIZION Unit’s ICB
must be first initialized using the USB Tool
Suite Utility Options. Refer to the JCM ICB
Installation Guide for exact programming
descriptions and operational details.