59
Self-contained refrigerating and freezing devices
-
Instruction manual
59
© JBG-
2 (v.
1
.
1
)
English
12.5.2
Setting the operating temperature
Follow the instructions below to bring up or program a set point
:
press the
SET
button for more than 2 second to bring up a set point,
use the
UP
or
DOWN
buttons to increase or decrease the set point as
appropriate to set its desired value,
press the
SET
button again or wait 10 seconds to confirm the entered value.
12.5.3
Manual defrosting
In order to turn on manual defrosting, press the DEF button for over 2 sec.
12.5.4
Alarms
Chamber sensor failure
P1
Evaporator sensor failure
P2
Maximum temperature alarm
HA
Minimum temperature alarm
L
A
Critical Alert
CA
Real-
time clock parameter error
rtC
Real-
time clock failure
rtF
58
Self-contained refrigerating and freezing devices
-
Instruction manual
English
© JBG-
2 (v.
1
.
1
)
12.5
XRi77CX DIXELL controller
12.5.1
Display and key functions
Symbol
Function
Preview of the current parameter map. In programming mode, change the
parameter or confirm.
Preview of the current parameter map. Changing a parameter in programming
mode. Holding for five seconds changes the parameter map.
Turns the device on/off.
Shows the current setting. Selecting and confirming a parameter in programming
mode.
Activates manual defrosting.
Lighting output control.
Symbol
Legend
Symbol
Legend
Lighting output status
Energy-
saving mode status
Compressor/cooling operation
status
Status of the Pull Down process
Operating parameters of fans
Alarm signalling
Status of
defrosting process
Current unit
AUX output status