Self-contained refrigerating and freezing devices
-
Instruction manual
57
© JBG-
2 (v.
1
.
1
)
English
Symbol
Legend
Symbol
Legend
Operating parameters of
compressor
Temporary defrost / combined
with real-time clock
Operating parameters of fans
Lighting output status
Status of defrosting process
Continuous duty cycle status
AUX output status
Status of the HACCP function
Errors (e.g. EEPROM errors, probe
error)
Alarm signalling
12.4.2
Setting the operating temperature
Follow the instructions below to bring up or program a set point:
press the
SET
button for more than 1 second to bring up a set point,
use the
AUX
or
DEF
buttons to increase or decrease the set point as
appropriate to set its desired value,
press the
SET
button again to confirm the entered value.
12.4.3
Manual defrosting
In order to turn on manual defrosting, press the
DEF
button for over 5 sec. (the
message “dFb” is going to appear for a while). Pressing the
DEF
button for longer
than 5 seconds causes defrosting to be switched off (the message “dFE” is going
to appear for a while)
12.4.4
Alarms
chamber sensor failure:
E0
low temperature alarm:
L0
defrosting sensor failure:
E1
high temperature alarm:
Hl
56
Self-contained refrigerating and freezing devices
-
Instruction manual
English
© JBG-
2 (v.
1
.
1
)
12.3.2
Setting the operating temperature
press and release the
SET
button, the display will show .set
press the
SET
button again, the display will show the set value
change the size by pressing the
UP
or
DOWN
buttons
pressing the
FNC
button twice or not pressing any button within 15 seconds
is going to cause the controller to return to normal operation
12.3.3
Manual defrosting
Defrosting is carried out automatically. It is however to force defrosting at any time
by pressing and holding the
UP
button for at least 5 seconds
12.4
IR33/IR33 + CAREL controller
12.4.1
Display and key functions
Symbol
Function
Changes parameters and their values. Holding down for extended periods turns
the adjustment on/off.
Changes parameters and their values. Holding down for extended periods turns
the AUX output on/off.
Cancelling the active alarm. Holding for three seconds starts the programming
mode.
Confirms settings. Holding down for one second allows to change the setpoint.
Holding for five seconds activates manual defrosting.