Diagram 2 :
Wiring for configuration
with
machine area access (example with gate)
5.4.10 Wiring of indicator light column on receiver
We strongly recommend that you wire an indicator light column on the receiver. The column will indicate the status of the
equipment and of the wireless enabling handle. The indicator light column status information panel should be fastened near to the
indicator light column (an example is given in the last page of this manual).
The consumption of the indicator lights of the column must not exceed 100 mA with 24VDC. If this is not the case, the indicator
lights should be relayed.
Status of lights on indicator light column
Indicator
light
On steady
Flashing
Off
Remarks
Green
Equipment in service
Equipment stopped
Red
Equipment stopped
Receiver on standby for
reset
Equipment in service
Red and orange indicator lights
will flash a specific number of
times in the event of a receiver
malfunction
Orange
Handle removed from
charger
Handle removed from
charger or area access
request
Handle on charger