Doc ref. :
332190D –
EN
28.04.2014
Page 16 / 49
5.3.6 Adjusting the machine area access time.
The machine area access time and the time during which the gate or safety light barrier is inhibited to allow
intervention in a machine area are configurable using the 2 «
A
» selectors on the receiver.
Important
: The 2 «
A
» selectors must be set to the same position to validate the selected time delay.
Position of «A»
selectors
0
1
2
3
4
5
6
7
8
9
Machine area
access time
5 s.
6 s.
7 s.
8 s.
9 s.
10 s.
15 s.
20 s.
25 s.
30 s.
Inhibit time (1)
(Muting)
5 s.
10 s.
20 s.
40 s.
1 min.
2 min.
3 min.
4 min.
5 min. 10 min.
Caution :
The machine area access time is the same as the enabling handle pickup time after it has been withdrawn
from its charger.
(1)
This time corresponds to the muting time of a gate or safety light barrier. Once the gate has been closed or the
barrier has been crossed, the muting function is stopped to prevent any unauthorised person from entering into the
area.