5.4 Receiver : operation and wiring
5.4.1 Operation and wiring of function outputs
The receiver is equipped with 6 solid state outputs (100 mA max). Assignment of the enabling handle buttons (B1 to
B4) with respect to the outputs depends on the operating mode selected using the RSP configuration software.
Assignment of receiver outputs in «
4 control buttons
» mode.
In the « 4 control buttons
»
mode
, buttons B1,
B2, B3 and B4 of the enabling handle respectively
control outputs 27, 37, 47 and 57.
Output 67 is activated as soon as one of the four
buttons is pressed (common output)
Reminder : If the receiver is managing machine area access, B1 and/or B2 and the associated outputs 27 and/or 37
are used to process the muting enable request for the gate or safety light barrier.
Assignment of receiver outputs in «
function selection
» mode.
This operating mode is configurable using the dialog RSP PC software.
In « function selection
»
mode
, buttons B3 and
B4 are used to select the machine component to
be controlled (F1 to F4) and buttons B1 and B2
are used to select the direction of movement.
Reminder :
Machine area access cannot be managed in the « function selection » operating mode.
Caution, the loads connected to the outputs must not deliver more than 100 mA with 24VDC.
Receiver RSRB outputs
27 37 47 57 67 77
Selection of
function by B3
and B4
F1
B1
X
X
B2
X
X
F2
B1
X
X
B2
X
X
F3
B1
X
X
B2
X
X
F4
B1
X
X
B2
X
X
Receiver RSRB outputs
27 37 47 57 67 77
B1
X
X
B2
X
X
B3
X
X
B4
X
X