Doc ref. :
332190D –
EN
28.04.2014
Page 15 / 49
5.3.4 Configuration of enabling handle operating mode
The wireless enabling handle operating mode can be configured using the Dialog RSP PC software supplied with the
handle.
This software is used to :
- Configure the handle in « 4 control buttons » or « function selection » operating mode.
- Modify the content of the screen display on the handle by loading or creating new pictograms.
- Save or re-load a new handle configuration in the SIM card of the handle.
- Re-load an old configuration.
5.3.5 Receiver : selecting the program
The receiver has 10 programs which can be selected using the two
« B »
selectors.
Access to the configuration selectors is obtained by removing the front panel of the receiver.
Important
: the 2 «
B
» selectors must be set to the same position to validate the selected program.
Position of
« B »
selectors
Reset mode, following a wired
emergency shutdown or
opening of a gate
Reset mode, following
release or clenching of the
handle trigger
Dangerous
area access
control
Remarks
0
Control console
Trigger
NO
1
Control console
Control console
NO
2
Automatic
Trigger
NO
3
Automatic
Control console
NO
4
Not used
5
Not used
6
Not used
7
Not used
8
Control console
Trigger
YES
The receiver module controls access to the
dangerous area using the handle.
9
Control console
Control console
YES
The receiver module controls access to the
dangerous area using the handle.
Note :
The « manual control » intervention mode cannot be used for programs 8 and 9.