12 Environmental data
According to EN 60947-1:2007 +A1:2011 clause 5.3, page 61:
NOTICE : This product has been designed for environment A. Use of this product may cause unwanted
electromagnetic disturbances in which case the user may be required to take adequate mitigation measures.
The altitude does not significantly affect the characteristics of RSRC receiver up to 2000 m. At higher altitudes, it is
necessary to take into account the reduction of the dielectric strength and the cooling effect of the air (EN 60947-5-1).
The table below shows the corrections to be made depending on the altitude for the relay contacts. The breaking
capacities remain unchanged. According to EN 60664-1 :
Altitude [m]
0
200
500
1000
2000
Lightning impulse withstand voltage [kV]
7.4
7.2
7
6.9
6
The relative humidity of the air does not exceed 50 % at a maximum temperature of +40°C. Higher relative humidities
may be permitted at lower temperatures, e.g. 90 % at + 20°C.
13 Residual risks
The product being an element of the equipment, a risk analysis of the concerned application will allow to estimate
these residual risks.
14 Foreseeable misuse
Polarity inversions of the safety receiver power supply
: no starting up of products.
Other misuse of the wireless enabling handle RSEP :
see
Diagnosis
paragraph.
Other misuse of the safety receiver RSRB :
see
Diagnosis
paragraph.
15 Contraindications
The wireless enabling handle RSEP should be changed after 233 hours of use.
16 Waste recycling and management
When the unit has reached the end of its service life, be sure to dispose of it appropriately. The
unit can be disposed of in a specific waste collection centre as organised by the local
authorities, or it can be turned over to a distributor who will handle proper disposal of the unit.
Electronic waste sorting will prevent possible negative impact on the environment resulting from
inappropriate elimination of electronic waste and will allow proper processing and recycling of
the materials forming the unit, representing signifi cant savings in terms of energy and
resources.
17 Manufacturer information
Head office and plant :
ZAC la Bâtie, rue Champrond
F38334 SAINT ISMIER cedex
Tel :
+33 (0)4 76 41 44 00
Fax :
+33 (0)4 76 41 44 44
www.jay –electronique.com