10.4 «IR start-up» option
The start-up zone for an equipment, and the equipment’s identification, can be secured by an IR validation on start-up.
To start the equipment, the operator must be inside the IR transmit zone of the
UDF
module (referred to as the «Start-
up zone») and actuate the trigger on the handle.
Once the validation has been performed, the «Handle/Equipment to be controlled» pairing takes place with no
possibility for error. The operator can then move around freely with no limitation.
The range of the IR start-up field of action is 0 to 3 m (see below).
The interconnect cable between the
UDF
and the
RSRB
can be extended by up to 2x10m for a total of 30m (the
original
UDF
-
RSRB
link being 10m) using an accessory (referenced
UDWR10
) comprising a shielded cable and its
connector.
10.4.1 Positioning the IR module UDF
10.4.2 Connecting the UDF module to the receiver
Black : A2-
White : A5+
Blue : IR
IMPORTANT :
The
UDF
module cables must be kept separate from the power cables and all other interference
generating sources (power regulator, for example).