3/4x17
4x6-1
1
4x6-14
4x6-17
4x6-17G
5x8-12D
V
5x8-14D
V
6x8-8
6x8-8G
6x8-12
6x8-12G
6x8-14
6x8-14G
6x8-17D
V
6x8-17G
DV
8x10-12D
V
8x10-12
G DV
Max liquid
temp with
quenching
gland
250°F
Max liquid
temp with
bearing cooling
Grease lube)
250°F
Max liquid
temp with
quench gland
and bearing
cooling
(Grease lube)
350°F
*1
Any part of which may be suction pressure.
*2
Water cooled bearings available for model 3405 only.
Table 5: Group L
6x8-22DV
8x10-14
8x10-14G
8x10-17
8x10-17G
10x12-12
10x12-14
10x12-14G
10x12-17
10x12-17G
12x14-12DV
12x14-14DV
Pump
Weight - bronze fitted
bare pump
1285
1330
1300 1385
1555
1600 1620
Casing thickness -
volute
11/16"
7/8"
7/8"
7/8"
7/8"
1"
7/8"
15/16"
Casing thickness -
side walls
1-3/16
"
¾"
¾"
¾"
¾"
¾"
¾"
¾"
Max diameter spheri-
cal solids
13/16" 1"
7/8"
¾"
7/8"
1-3/4" 1"
1-11/1
6"
¾"
1-1/4" 1-3/4"
Casing capacity -
gallons
21.0
19.5
24.9
25.0
29.3
33.0
35.5
Stuffing
box
Stuffing box bore
3-1/4"
Stuffing box depth (to
stuffing box bushing)
3-1/8"
Stuffing box packing
size
3x8' x 3/8"
Stuffing box - no. of
packing rings
6
Width of lantern ring
7/8"
Shaft
Shaft diameter at im-
peller
2-3/16"
Shaft diameter in
shaft sleeve
2-3/16"
Shaft diameter at
coupling end
1-15/16"
7.3 Sectional view
3405-3406-3416 Installation, Operation and Maintenance Instructions
43
Содержание Goulds Pumps 3405
Страница 1: ...Installation Operation and Maintenance Instructions 3405 3406 3416 ...
Страница 2: ......
Страница 19: ...Figure 6 2 5 Install suction piping 3405 3406 3416 Installation Operation and Maintenance Instructions 17 ...
Страница 41: ...7 3 Sectional view 7 3 Sectional view 3405 3406 3416 Installation Operation and Maintenance Instructions 39 ...
Страница 42: ...7 3 Sectional view 40 3405 3406 3416 Installation Operation and Maintenance Instructions ...