Figure 7:
2.6 Piping - discharge
1.
A gate valve and a check valve should be installed in the discharge line. The check valve should
be located between the gate valve and pump to permit inspection of the check valve. The gate
valve is required for priming, regulation of flow capacity and for inspection and maintenance of
the pump. See
.
2.
lncreasers, if used in discharge line, should be placed between the check valve and the pump.
2.7 Connection of piping
Connect suction and discharge piping. Rotate the pump shaft by hand several complete revolutions to be
sure that there is no binding and that all parts are free. Recheck alignment as described in Section Align-
ment - initial. If the connection of the piping causes unit to be out of alignment, correct piping to relieve
strain on the pump.
2.8 Check rotation
The direction of rotation is marked on the pump casing. Make sure that driver rotates in the same direc-
tion. On electric motors, jog starting switch to be sure wiring is connected for correct rotation. Be sure
that coupling is disconnected.
2.9 Connection of coupling
Connect coupling, following instructions for the particular make of coupling furnished. This data is sup-
plied separately, giving complete instructions for connection, lubrication, alignment and maintenance.
NOTICE:
Pumps and drivers are bedplated so that when coupling faces are positioned in accordance
with the manufacturer's recommended gap, there is an overhang of approximately 1/8" from
shaft ends to coupling hub faces.
1.
Model 3405 - between 180ºF and 250ºF when bearing housings are not cooled and between
250º and 350ºF, in addition to bearing housing cooling.
2.6 Piping - discharge
18
3405-3406-3416 Installation, Operation and Maintenance Instructions
Содержание Goulds Pumps 3405
Страница 1: ...Installation Operation and Maintenance Instructions 3405 3406 3416 ...
Страница 2: ......
Страница 19: ...Figure 6 2 5 Install suction piping 3405 3406 3416 Installation Operation and Maintenance Instructions 17 ...
Страница 41: ...7 3 Sectional view 7 3 Sectional view 3405 3406 3416 Installation Operation and Maintenance Instructions 39 ...
Страница 42: ...7 3 Sectional view 40 3405 3406 3416 Installation Operation and Maintenance Instructions ...