5.
Slide cup washers over shoulders of gland flanges and tighten nuts evenly to provide proper
pressure against stuffing box packing. Gland bolts do not screw into tapped holes in casing. Tap-
ped holes in casing are for mechanical seal gland only when pumps are furnished with seals.
1.
Model 3405 - Between 180°F and 250°F when bearing housings are not cooled and between
250°F and 350° F, in addition to bearing housing cooling.
2.
Model 3406 - Between 180° and 250°F.
3.
Model 3416 - Between 250° and 350°F when bearing housings are not cooled and between 350°
and 400°F, in addition to bearing housing cooling.
3.5 Connection of piping to quenching gland
3405-3406-3416 Installation, Operation and Maintenance Instructions
25