3.
Piping must not be connected to the pump until the grout has thoroughly hardened and the foun-
dation bolts as well as driver and pump hold-down bolts have been tightened. See Section
2.7 Connection of piping on page 18
.
4.
When handling liquids at elevated temperatures, arrangements must be made for expansion
loops or expansion joints so that the linear expansion of the pipe will not cause the pumping unit
to be drawn out of alignment.
2.5 Install suction piping
1.
General - properly installed suction piping is of extreme importance for trouble-free centrifugal pump
operation.
a) The suction pipe should be as large or larger than the pump suction.
b) lncreasers, if used, should be eccentric and preferably at the pump suction flange, sloping side
down.
c)
A centrifugal pump should never be throttled on the suction side for capacity adjustment.
d) When more than one pump is operating from the same source of supply, separate suction
lines, if possible, should be used. If not possible for separate lines, piping arrangement as
shown in
2.5 Install suction piping
14
3405-3406-3416 Installation, Operation and Maintenance Instructions