recommended for water, ammonia, mild chemicals and all general services, and is good for the maxi-
mum temperatures for which the pumps are rated.
It is suggested that the packing rings be allowed to soak in #10 SAE oil for 15 minutes to one hour prior
to installation.
When installing the packing and the PTFE lantern ring, twist the rings sideways just enough to get them
around the shaft sleeves. Do not attempt to pull rings straight out to get them over shaft and shaft sleeve.
(See
Figure 11:
Insert two rings of packing for Group "S" & "M" pumps and three rings for Group ''L'' pumps against the
stuffing box bushings (125), staggering the joints. See
(105) should then be inserted in the stuffing box. When it is in its proper position, it will be directly oppo-
site the sealing inlet connection.
After the lantern ring is in place, insert three more rings of packing, staggering the joints. Two extra rings
of packing are furnished in each set of packing. The extra ring for each side may be added as required.
Insert gland packing (210) into recess in each gland half and trim off excess flush with face of each gland
half.
Now, insert lower half gland (107) into stuffing box. Run ½"-20 SAE nuts (355) about three-fourths the
length of the threaded part of bolts (353) and place cupped washers (354) on gland bolts.
Insert round, flattened end of gland bolts into recesses of bearing housing (134 or 166) on Model 3405,
or into recesses of bearing housing cover (160) on Model 3406. Threaded portion of gland bolts lays on
gland half.
Insert upper half gland into stuffing box. Place cupped washers over the bosses on the gland to hold the
gland halves together.
Draw the gland nuts up evenly but not tight.
Stuffing Boxes With Mechanical Seals:
When mechanical seals are furnished they are installed at the factory and no further adjustments are re-
quired.
When single mechanical seals are used, the water seal piping must be connected as explained in
3.4 Connection of water seal piping on page 23
When double mechanical seals are used, the water seal piping is omitted and the four holes in stuffing
box and casing must be plugged. Cooling liquid from an outside source must be piped to the gland open-
ings at a pressure slightly more than the suction pressure of the pump.
The two gland openings are tapped for 1/8" pipe.
3.3 Stuffing boxes
22
3405-3406-3416 Installation, Operation and Maintenance Instructions
Содержание Goulds Pumps 3405
Страница 1: ...Installation Operation and Maintenance Instructions 3405 3406 3416 ...
Страница 2: ......
Страница 19: ...Figure 6 2 5 Install suction piping 3405 3406 3416 Installation Operation and Maintenance Instructions 17 ...
Страница 41: ...7 3 Sectional view 7 3 Sectional view 3405 3406 3416 Installation Operation and Maintenance Instructions 39 ...
Страница 42: ...7 3 Sectional view 40 3405 3406 3416 Installation Operation and Maintenance Instructions ...